Electrical Shock Hazard
Disconnect power before servicing.
Replace all panels before operating.
Failure to do so can result in death
or electrical shock.
N
W
L1
BK
W
W
W
BK
BK
P4-4
R
P4-5
P3-1
P3-2
P2-1
P2-4
P4-1
BR
BU
BU
V
R
BROIL IGNITOR
BAKE IGNITOR
BAKE VALVE
BROIL VALVE
N.O.
COM
DOOR
LATCH SW.
DOOR LOCK
SOLENOID
W
GND
OVEN LT.
P3-3
P3-4
P3-6
P3-7
P2-2
P2-3/P6
GND
G
P3-5
P4-3
OVEN
TEMP
SENSOR
DOOR
SW.
OVEN CONTROL
V
V
SURFACE BURNER
IGNITION SWITCHES
SPARK MODULE
Y
Y
R
BU
BK
M
BI - METAL SW FAN N.O.
BI-METAL SW
AMBIENT N.C.
Y
Y
W
BK
BK
TRANSFORMER
OVEN LIGHT RELAY
LATCH RELAY
BROIL RELAY
BAKE RELAY
Caution: Label all wires prior to disconnection
when servicing controls. Wiring errors can
cause improper and dangerous operation.
Verify proper operation after servicing.
NOTE: Drawing shows door latch switch in the cook
position with oven door open, oven off and light on.
TECH SHEET - DO NOT DISCARD
PAGE 1
FOR SERVICE TECHNICIAN'S USE ONLY
PART NO. 9753053