GAS VALVE
Electrical Shock Hazard
Disconnect from electrical supply before ser-
vicing unit.
Failure to do so could result in electrical
shock or other personal injury.
WARNING
Test Procedure
Refer to page 4-6 for the location of the gas
valves and the procedure for servicing them.
To test a gas valve, perform the following step:
Use a low-pressure manometer, and measure
the inlet and outlet pressure across the valve.
There should be no pressure drop. If there is a
pressure drop, the valve should be replaced.
SPARK IGNITOR
NOTE: All of the ignitors should spark at the
same time, regardless of which valve is turned
on.
BLK
WHT
SPARK MODULE
IGNITOR
SWITCH
L1
N
WHT
GRN
IGNITOR
Spark Ignitor