Test Procedure
HOT SURFACE INDICATORS
To test a limiter, perform the following steps:
1.
Use an ohmmeter and set the range to
R x 1.
2.
With no power applied, touch the ohmme-
ter leads to the following terminals. You
should obtain the following readings at
the indicated temperature:
1A and 2A opens @ 1025˚F
1B and 2B closes @ 275˚F
If the readings are not within the range shown,
the limiter is defective and should be replaced.