3-2
REMOVING THE OPEN COIL MAINTOP
WARNING
SCREW
CONNECTOR
BLOCK
5.
Remove the screws from the element con-
nector blocks and lay the blocks on the burner
box.
Electrical Shock Hazard
Disconnect from electrical supply before servic-
ing unit.
Failure to do so could result in death or electrical
shock.
6.
Lift the maintop and remove the ends of the
support rods from the sides of the body. Be
careful not to scratch the body sides.
CAUTION:
When you work on the electric range,
be careful when handling the sheet metal parts.
Sharp edges may be present, and you can cut
yourself if you are not careful.
1.
Turn off the electrical supply to the range.
2.
Make sure that the coil elements are cool
before you handle them.
3.
Push and lift the coil elements and unplug
them from the connector blocks, then remove
them from the maintop.
4.
Remove the drip pans from the maintop.
RAISE MAINTOP