2.4 TECNICAL DATA TABLE FOR THE WATER SYSTEM
4-5 trays
6-7 trays
10-12 trays
Water flow rate regulator for
steam generation in combined
cycle.
Ø 0.4 mm
Ø 0.4 mm
Ø 0.5 mm
Water flow rate regulator for
steam generation in steam cycle.
Ø 0.55 mm
Ø 0.6 mm
Ø 0.6 mm
2.5 HYDRAULIC CONNECTION – WATER INLET
The ovens have 2 water inlet coupling at the right side.
It is necessary to connect both.
Always install an on-off valve between the appliance
and the water mains, making sure it is easy to oper-
ate.
We also suggest installing a cartridge filter on the wa
-
ter inlet pipe.
Always use a set of new water joints, eventual
old joints must not be used again.
Plumbing connection must be always effected with cold
water and rigid pipes.
Never use hoses to connect the oven to the water
main.
2.6 PLUMBING – WATER DRAINAGE
Drainage for the water is at the back of the oven and must be connected
directly to the end of the stainless steel drainpipe.
The drain must have no trap and be made in rigid pipes that can with-
stand a temperature of 110°C.
Under no circumstances must pipe diameter be reduced. The actual pipe
should be at atmospheric pressure with the appropriate funnel type air
intake.
If the drainpipe is clogged for any reason steam can escape from the
door and bad smells can be created inside in the oven.