3.2.1 Table mounted eye showers:   

Install using the table mounting accessories M28x80mm. A hole of 30 mm diameter should 

be made in the table top at a suitable point. 

The table mounting accessories will be mounted with the plastic rosette and the counter nut 

below the table surface.  

3.2.2 Wall mounted eye showers: 

Install using the wall flange. The wall flange should be installed with a suitable fastening 

system on a flat surface (wall). 

Installing using the male thread: Remove the bottom of the eye shower. Drill the embossed 

holes and arrange the eye shower and mark the mounting holes.

3.2.3 Wall-/table mounted hand-held eye showers:       

Install using the combined wall and table bracket. When using the combined bracket as a 

wall bracket, the brass pipe must be unscrewed by hand - ensure that work gloves are worn 

for this. The wall  bracket should be mounted  on an even surface (wall) using a suitable  

fixing  system. To  achieve a wall spacing of 150  mm  according to DIN EN 15154-2:2006, an 

additional spacer (article number: BR 710 255) is available as an accessory. When using as a 

table bracket, refer to the points under 4.2.1.      

3.2.4 Wall mounted hand-held eye showers, 45° wall mounted:       

Install using the 45° wall bracket. The wall bracket should be mounted on an even surface 

(wall) using a suitable fixing system.       

3.2.5 25°-table mounted hand-held eye shower:

Install using the 25° table mounting accessories M28x80mm. A hole of 30 mm diameter 

should be made in the table top at a suitable point. The table mounting accessories will be 

mounted with the plastic rosette and the counter nut below the table surface.       

3.3 Position of strainer and gasket (Hand-held eye showers) 

The strainer must be mounted between the eye shower and the hose; the gasket must be 

mounted between the water inlet and the hose. 

4. Water supply 

The FAR eye shower should be connected to drinking water. The drinking water system 

should be constructed in accordance with DIN 1988 and DIN EN 1717. 

CAUTION! For new installations the water supply system must be rinsed out before 

connecting the shower in order to prevent dirt damaging the valve. 

4.1 Water supply for hand-held eye showers

The FAR hand-held eye shower is connected to the water supply using the ½ inch connection 

nut on the hose. The FAR hand-held eye showers are fitted with a backflow preventer 

according to DIN 1988 protection class 2 (3 for short periods). In addition, a second backflow 

preventer can be obtained from specialized traders to achieve a higher protection class.

10

PRODUCT MANUAL

1800 358 101

[email protected]

www.westlab.com.au

09 972 7682

[email protected]

www.westlab.co.nz

646 568 5391

[email protected]

www.westlab.com

1 877 822 1455

[email protected]

www.westlab.com

Australia

New Zealand

United States

Canada

Summary of Contents for 664-812

Page 1: ...1 PRODUCT MANUAL Product Manual Floor Mounted Emergency Shower Head Eye Wash Code 664 812...

Page 2: ...Coated Surface Protection Hand Foot Operated 100 Italian Made 2 Technical Specifications Application Floor Fixed Test Pressure 9 bars air Working Pressure Max 5 bars Flow Rate 30L min at 1 bar Surfac...

Page 3: ...uidelines 2 Operating pressure The FAR safety showers are designed for an operating pressure of a maximum of 10 bar PN 10 The flow rate is dependent on the available water pressure as well as the cros...

Page 4: ...o be safely drained away using barriers and drain trays if necessary 3 1 Water connection The connections for the various safety showers have a to 1 thread We recommend attaching the safety shower to...

Page 5: ...4 5 1 Models with safety eye showers combine the eye shower and body safety shower using the provided adapter 4 5 2 Models with hand held eye showers mount the bracket of the hand held eye shower at a...

Page 6: ...must be deinstalled during this process It must be reinstalled after the rinsing process The high performance shower head can be fastened and tightened using a pin type face wrench item no BR 010 100...

Page 7: ...the shower 9 3 Models with safety eye showers In order to start the eye shower press the big PUSH lever This locks the PUSH lever in the open position The eyewash should not make direct contact with t...

Page 8: ...is too low Water pressure is too low supply line cross section is too small or the jet regulator is contaminated The valve does not close properly The valve seal is damaged This is NOT a fault This is...

Page 9: ...eye shower irrespective of the existing operating pressure 2 2 Eye showers with two high performance spray heads To guarantee correct operation the flow pressure must be at least 2 bar The flow rate i...

Page 10: ...able fixing system 3 2 5 25 table mounted hand held eye shower Install using the 25 table mounting accessories M28x80mm A hole of 30 mm diameter should be made in the table top at a suitable point The...

Page 11: ...t possible to hold open the lids of the contaminated eyes with both hands at the same time The shower can also be removed from the bracket This allows other body parts or an injured person on the floo...

Page 12: ...have started to leak This is generally due to dirt from the water supply which collects in front of the valve If this has happened disconnect the handheld eye shower from the supply Operate the shower...

Reviews: