4. Installation 

4.1 Installation of wall/ceiling mounted versions 

Wall or ceiling mounted versions must be securely fastened to the wall/ceiling or other 

special structure. The technique required to fasten the shower depends on the construction 

and is to be decided by the installation company. 

4.2 Installation of over-door mounted versions 

The over-door models are delivered with an already attached valve adapter (type A) for 

installation of the rod-operated valve to the right of the door. If an installation to the left of the 

door is required, then the attached valve adapter (type A) must be replaced by another valve 

adapter (type B), which is also included in the delivery. The specialist tool (C31), which is also 

included in the delivery, must be used to attach the valve adapter to the ball cock. The nut of 

the ball cock must be tightened with a standard screw locking device. 

4.3 Installation of freestanding body safety showers 

Freestanding body safety showers must be securely fastened to the surface using the base 

plate. The technique required to fasten the shower depends on the construction and is to be 

decided by the installation company. 

4.4 Installation of safety shower cubicles 

Safety shower cubicles must be securely screwed to the subfloor by means of the base 

plates. The technique required to fasten the shower depends on the construction and is to be 

decided by the installation company. 

4.5 Models with eye showers 

4.5.1  Models with  safety eye showers combine the eye shower and body safety shower using 

the provided adapter 

4.5.2  Models with  hand-held eye showers mount the bracket of the hand-held eye shower 

at a height of approximately 900 mm. Connect the hand-held eye shower to the body 

safety shower with the hose using the double adapter. 

4.5.3  Models with eye/face wash units remove the base of the eye shower. Drill the holes for 

the pipe clamps using the template provided. Place the eye shower at a height of 970 

mm on the body safety shower and fasten it using the pipe clamps, screws and nuts. 

Install the base. Connect the eye shower to the body safety shower with the hose using 

the double adapter. 

4.6 Models with optional platform actuation 

Platform actuators must be securely screwed to the floor. Which type of fasteners are 

required must be determined at the installation site by installation personnel depending upon 

the type of foundation. 

The actuating chain is cut to length at the factory. During setup at the installation site, it 

must be assured that the actuating chain opens the valve all the way when the platform is 

subjected to full loading, but it must also have a small amount of remaining free play. If there 

is no free play, for example due to an out-of-level foundation, the chain must be lengthened 

because the shower valve will otherwise be damaged. 

5

PRODUCT MANUAL

1800 358 101

[email protected]

www.westlab.com.au

09 972 7682

[email protected]

www.westlab.co.nz

646 568 5391

[email protected]

www.westlab.com

1 877 822 1455

[email protected]

www.westlab.com

Australia

New Zealand

United States

Canada

Summary of Contents for 664-812

Page 1: ...1 PRODUCT MANUAL Product Manual Floor Mounted Emergency Shower Head Eye Wash Code 664 812...

Page 2: ...Coated Surface Protection Hand Foot Operated 100 Italian Made 2 Technical Specifications Application Floor Fixed Test Pressure 9 bars air Working Pressure Max 5 bars Flow Rate 30L min at 1 bar Surfac...

Page 3: ...uidelines 2 Operating pressure The FAR safety showers are designed for an operating pressure of a maximum of 10 bar PN 10 The flow rate is dependent on the available water pressure as well as the cros...

Page 4: ...o be safely drained away using barriers and drain trays if necessary 3 1 Water connection The connections for the various safety showers have a to 1 thread We recommend attaching the safety shower to...

Page 5: ...4 5 1 Models with safety eye showers combine the eye shower and body safety shower using the provided adapter 4 5 2 Models with hand held eye showers mount the bracket of the hand held eye shower at a...

Page 6: ...must be deinstalled during this process It must be reinstalled after the rinsing process The high performance shower head can be fastened and tightened using a pin type face wrench item no BR 010 100...

Page 7: ...the shower 9 3 Models with safety eye showers In order to start the eye shower press the big PUSH lever This locks the PUSH lever in the open position The eyewash should not make direct contact with t...

Page 8: ...is too low Water pressure is too low supply line cross section is too small or the jet regulator is contaminated The valve does not close properly The valve seal is damaged This is NOT a fault This is...

Page 9: ...eye shower irrespective of the existing operating pressure 2 2 Eye showers with two high performance spray heads To guarantee correct operation the flow pressure must be at least 2 bar The flow rate i...

Page 10: ...able fixing system 3 2 5 25 table mounted hand held eye shower Install using the 25 table mounting accessories M28x80mm A hole of 30 mm diameter should be made in the table top at a suitable point The...

Page 11: ...t possible to hold open the lids of the contaminated eyes with both hands at the same time The shower can also be removed from the bracket This allows other body parts or an injured person on the floo...

Page 12: ...have started to leak This is generally due to dirt from the water supply which collects in front of the valve If this has happened disconnect the handheld eye shower from the supply Operate the shower...

Reviews: