18
Water and Milk Connection
3.6 Water and Milk Connection
Water connection
Milk connection
3.6.1 Water Connection
:
Connect the 1/2“ water hose with a 3/4“ hose coupling at the right of the automatic calf
feeder.
The water pressure supplied by customer has to be between 2,5 and 6 bar.
Note
: To ensure troublefree functioning of the automatic feeder, take care that the water
pressure does not fall below 2,5 bar!
Take care that there is no pressure variation of the water pipe.
In case of water pipes with small cross section it may happen that, in the feeding mode or
when water is taken out of the same pipe simultaneously, the water pressure will drop.
When the water pressure is below 2,5 bar you have to use a header tank.
Install additional water stop valve.
Since September 1, 2000 the pressure reducer is factory--set to 1,5 bar.
Do not alter the setting of the pressure reducer!
In case the notes above should not be observed, there is no guarantee that the automatic
feeder will run trouble- free!