CP600 Pivot Operation Manual
POM-EN-Dec
ember 20
18
106
Section 4-8
Panel Operation
Auto Reverse / Auto Off Option
The CP600 Auto Reverse / Off option is designed for both End Tower and Pivot Point op-
eration. It uses the direction wires in the span cable to send a momentary pulse signal to
the main control panel.
The Auto Reverse Switch is located at the End Tower or Pivot Point and uses a Normally
Open contact to pulse the wire of the desired direction to actuate the relay in the main
panel. If the system is running in Forward and the direction switch is in the Auto position,
a pulse on the Reverse wire will change the direction of the machine. The logic is re-
versed for changing from Reverse to Forward.
Reference the following steps to assist you in the successful operation of this feature:
Auto Reverse Option:
1. Turn the Rev-Auto-Fwd switch (1) to the Auto position.
2. Turn the Stop-Run-Start switch (3) to the Start position.
When the machine is started with the Start switch (item 3) it should run in the direction
that it was last running. If the opposite direction is desired, start the system with the
switch in the desired direction, then move it back to Auto.
Auto Off Function:
The Auto Off function is a built-in feature of the Auto Reverse option. To operate the Auto
Off function:
1. Place the Rev-Auto-Fwd switch in the desired direction of travel of the machine.
2. Turn the Stop-Run-Start switch (3) to the Start position.
When the Auto Reverse switch is operated at either the barricade or pivot point, the ma-
chine will shut down. To restart the machine:
1. Return the Rev-Auto-Fwd switch to either the Auto position or the new direction.
2. Turn the Stop-Run-Start switch to Start position.
Summary of Contents for CP600
Page 1: ...CP600 Pivot Operation Manual POM EN December 2018 ...
Page 2: ...2 This Page Intentionally Left Blank ...
Page 5: ...5 POM EN December 2018 CP600 Pivot Operation Manual Section 1 Operation Safety Maintenance ...
Page 6: ...6 This Page Intentionally Left Blank ...
Page 41: ...CP600 Pivot Operation Manual POM EN December 2018 41 Section 2 General Information ...
Page 83: ...CP600 Pivot Operation Manual POM EN December 2018 83 Section 3 Getting Started ...
Page 89: ...89 This Page Intentionally Left Blank ...
Page 98: ...98 This Page Intentionally Left Blank ...
Page 99: ...CP600 Pivot Operation Manual POM EN December 2018 99 Section 4 Panel Operation ...
Page 112: ...112 This Page Intentionally Left Blank ...
Page 113: ...CP600 Pivot Operation Manual POM EN December 2018 113 Section 5 Electrical ...
Page 119: ...119 This Page Intentionally Left Blank ...
Page 123: ...123 This Page Intentionally Left Blank ...
Page 128: ...CP600 Pivot Operation Manual POM EN December 2018 128 Section 5 16 Electrical Notes ...
Page 129: ...CP600 Pivot Operation Manual POM EN December 2018 129 Section 5 17 Electrical Notes ...
Page 130: ...CP600 Pivot Operation Manual POM EN December 2018 130 Section 5 18 Electrical Notes ...
Page 131: ...CP600 Pivot Operation Manual POM EN December 2018 131 Section 5 19 Electrical Notes ...
Page 132: ...132 This Page Intentionally Left Blank ...
Page 133: ...133 Section Title This Page Intentionally Left Blank ...
Page 134: ...134 POM EN December 2018 www western irrigation com ...