251
6620-3201
Pro
fi
le 50 is automatically loaded when a PAD is
fi
rst activated. To load one of the other pre-de
fi
ned
pro
fi
les use the PROF command followed by the required pro
fi
le number. For example:
PROF 90
To create a User PAD pro
fi
le you must use the SET command to con
fi
gure the various PAD
parameters to suit your application and then use the PROF command in the format:
PROF &nn
where “nn” is the number of the User PAD pro
fi
le to be stored, e.g. 03. Alternatively, you may use the
web interface to edit the parameter tables directly (
Confi gure
>
X25 PADs
>
Parameters
).
The pre-de
fi
ned pro
fi
les (50, 51, 90, 91), cannot be overwritten and are permanently con
fi
gured as
shown in the following table:
Parameter Profi le
50 51 90 91
1 1
0
1
0
2 0
0
1
0
3 0
0
126
0
4 5
5
0
20
5 0
3
1
0
6 5
5
1
0
7 0
8
2
2
8 0
0
0
0
9 0
0
0
0
10 0
0
0
0
11 15
15
15
15
12 0
3
1
0
13 0
0
0
0
14 0
0
0
0
15 0
0
0
0
16 8
8
127
127
17 24
24
24
24
18 18
18
18
18
19 2
2
1
1
20 64
64
0
0
21 0
0
0
0
22 0
0
0
0
Stored X.25 PAD pro
fi
les are held in non-volatile memory and will not be lost when the unit is
switched off.
When used in the format:
prof nn
the PROF command loads the stored pro
fi
le speci
fi
ed by “nn”.
10.4.9 RESET Send Reset Packet
RESET is used to issue a reset for the current call to the network. It does NOT clear the call but it
does return the network level interface to a known state by re-initialising all Level 3 network control
variables. All data in transit will be lost.
10.4.10 RPAR? Read Remote X.3 Parameters
RPAR? lists the current X.3 parameter settings for the remote system.