217
6620-3201
4.91.8 8 Discard Output
This parameter determines whether data received during a call is passed to the DTE or discarded. It
can only be directly set by the remote system and may be used in a variety of circumstances when
the remote DTE is not able to handle a continuous
fl
ow of data at high speed.
Option Description
0
Normal data delivery to DTE
1
Output to DTE discarded
4.91.9 9 Padding after CR
Slower terminal devices, such as printers, may require a delay after each Carriage Return before they
can continue to process data. This parameter controls the number of pad characters (NUL - ASCII 0)
that are sent after each CR to create such a delay.
Option Description
0
No padding characters after CR
1-255
Number of padding characters (NUL) sent after CR
4.91.10 10 Line Folding
Controls the automatic generation of a [CR],[LF] sequence after a certain line width has been
reached.
Option Description
0
No line folding
1-255
Width of line before the PAD generates [CR],[LF]
4.91.11 11 Port Speed
This is a “read only” parameter, set automatically by the PAD and accessed by the remote system.
Option Description
15 19,200
bps
14 9,600
bps
12 2,400
bps
3 1,200
bps
4.91.12 12 Flow Control of PAD (by DTE)
Determines the
fl
ow control setting of the PAD by the DTE in the on-line data state.
Option Description
0 No
fl
ow control
1 XON/XOFF
fl
ow control
3 RTS
fl
ow control (not a standard X.3 parameter)