50
WellGate FXO GateWay User Manual
S/W version:x4fxo.116a
group -enable
group -disable
group -number 2 -pattern 3 3 -e164 01 02
group -pattern 3 1 -e164 100 200
group -e164 11 22
Parameter Usages:
- print : display current grouping information
- enable : enable grouping function
- disable : disable grouping function
- number : set how many groups will be divided
- pattern : set how many members in each group
- e164 : set e164 of each group
For ex: if users need to divide WellGate FXO GateWay into L1 in the 1
st
group,
and L2 in the 2
nd
group), and have them register to gatekeeper separately
(e164=100 for 1
st
group; e164=200 for 2
nd
group). They have to use the
following command:
-------------------------------------------------------------------------------------------------
usr/config$ group – pattern 1 3 – e164 100 200
Note: GROUP function is effective only in gatekeeper mode.
5.21 [bureau] command
Type
bureau
to display the command usage.
-------------------------------------------------------------------------------------------------
usr/config$ bureau
Bureau line setting information and configuration
Usage:
bureau [-pstn number] [-hold used] [-table [Port DestIP TELnum]]
bureau -print
Display Bureau line informatio and configuration.
-pstn
PSTN number (per port basis). This number is used to display
as a caller ID when the caller ID is not available.
The maximum digit length is 32.
-hold
Specify the hold tone generation (using PCM file). (On/Off)
Setting value (On=1, Off=0).
-table
Set Hot line/Line To Line information. (Port range: 1~2)