4.2 How to configure disconnect tone on WellGate FXO GateWay
gateway
WellGate FXO GateWay has a default setting of disconnect tone (Busy tone 1,
Busy tone 2, reorder tone 1 and reorder tone 2 ). If the disconnect tone was
recognized correctly, the LINE port from PSTN/PBX will be released in two
seconds. Otherwise it may be released after one minute or lock this LINE
permanently.
The tone table parameters are shown as follows.
LowFreq 480 : Low frequency is 480 HZ
HighFreq 620 : High frequency is 620 HZ
LowFreqLevel 8
: Low frequency level received range from PSTN/PBX
HighFreqLevel 8
: High frequency level received range from PSTN/PBX
TOn1
50
: Disconnect tone cadence ON time is 0.5 seconds
TOff1
50
: Disconnect tone cadence OFF time is 0.5 seconds
( If this is continuous tone, the Toff has to set to 1023 )
TOn2
1023
: Disconnect tone second cycle cadence ON time is
OFF TOff2
1023
: Disconnect tone second cycle cadence OFF time
is OFF
( If the tone cadence has only one cycle, the second cycle must set to 1023 )
(1) Examples how to configure Tone table
a. 480/620 frequency with ON/OFF time is 0.5 seconds
tone -busy1 480 620 8 8 50 50 1023 1023
b. 480 HZ single frequency with continuous tone
tone –reorder2 480 0 8 0 50 1023 1023 1023
(2) There are two ways to analyze the disconnect tone.
a. The first one is using command “greetrd” from WellGate FXO GateWay. Once
you follow the instruction to analyze the disconnect tone, Gateway will
configure the tone table (Busy tone 1, Busy tone 2, reorder tone 1 and reorder
tone 2 ) with proper frequency and default tone level and cadence (Ton1/Toff1)
automatically. Or you may read the analysis tone frequency from command line
and configure to one of tone table manually.
The default tone level is set to 8. And the tone cadence (Ton1/Toff1) is set to
four different values on tone table. They are 0.1 second, 0.25 seconds, 0.5
seconds and 0.75 seconds with parameters 10/10, 25/25, 50/50 and 75/75.
If the PBX/PSTN cadence is not the value as default shown as above, you
need to use the following instruction to analyze ON/OFF intervals.
b. You may use your PC (START
Program Files
Accessories
Multimedia
Recorder) with Headset or Microphone to record the disconnect tone via a
telephone set from PSTN/PBX and save to a voice file. Then you can use
“CoolEdit Pro” software to analyze the frequency and ON/OFF time. Please visit
http://www.cooledit.com to download demo version for analysis. You can use this
program to analyze ON/OFF time and fill in to tone table.