It is recommended that type the “
quit
” command before you leave the console.
If so, WellGate FXO GateWay will ask password again when next user connects to
console port.
5.3 [debug] command
Open debug message will show up specific information while WellGate FXO
GateWay is in operation. After executing the debug command, it should
execute command
debug -open
as well. One example is demonstrated
below.
usr/config$ debug -add h323 vp
usr/config$ debug -open
Parameters Usage:
-status
Display the enabled debug flags.
-add
Add debug flag.
-- h323 : h323 related information
-- vp : voice related information
-delete
Remove specified debug flag.
-open
Start to show debug messages.
-close
Stop showing debug messages.
5.4 [reboot] command
After
commit
command, type
reboot
to reload WellGate FXO GateWay in new
configuration. The procedure is as below:
usr/config$ reboot
Attached TCP/IP interface to cpm unit 0
Attaching interface lo0...done
AC4804[0] is OK
AC4804[1] is OK
AC4804[2] is OK
Successful
Initialize OSS libraries...OK!
open stack successful
cmInitialize succeed!
GK mode selected.