Well Bubbler 10-120 Installation And Configuration Manual Download Page 21

THE WELL BUBBLER

WWW.WELLBUBBLER.COM

CONFIGURATION: START PUMP LEVEL

The Well Bubbler is equipped with a pump control relay, which can be used to stop the
pump when the water level is low, and to re-start the pump as the water level recovers.
This relay is typically wired to a pump control panel HAND / OFF / AUTO switch.

Set the Start Pump Level to the well level at which the pump should safely start. This 
value is typically determined by the net positive suction head (NPSH) requirement of  the
pump itself.

Note that the pump control relay operates based on the instantaneous air line pressure,
and will react immediately to protect the pump, without waiting for the scheduled 
well level sample.

DRAWN BY: A. BUGROV

DATE: 02.20.2021

PAGE: 21

Summary of Contents for 10-120

Page 1: ...THE WELL BUBBLER WWW WELLBUBBLER COM INSTALLATION AND CONFIGURATION MANUAL MODEL 10 120 MODEL 10 300 DRAWN BY A BUGROV DATE 02 20 2021 PAGE 1...

Page 2: ...channel strut manufactured by UniStrut and U Line Begin the sensor installation by mounting the strut near the well head either on a tripod as shown below or on a backboard Orient the open face of the...

Page 3: ...the Well Bubbler on the channel strut using the 1 2 13 fasteners included with the unit Tighten the fastener using a 3 4 wrench note that the entire weight of the unit is supported by this fastener t...

Page 4: ...ELLBUBBLER COM INSTALLATION STEP 3 Insert the 1 4 OD tubing into the push to connect fitting as shown below Depress the green push ring and pull the tubing to remove it if necessary DRAWN BY A BUGROV...

Page 5: ...s fuse with any other type or rating spare fuses are shipped with the sensor The display should now activate note that the Well Bubbler may begin operating once the fuse is installed Refer to the foll...

Page 6: ...ht this feature is useful in low light and will turn off automatically to conserve energy Press the center button again to move or toggle between different menus Right press this button to increase a...

Page 7: ...urrent pressure in the airline in PSI and the associated well level Stat the status indicator shows the operating mode of the unit Testing Waiting etc t the timer showing the duration of the current t...

Page 8: ...NTRAST ADJUSTMENT The Bubbler adjusts the display contrast automatically based on the display temperature to improve visibility in bright sunlight This menu can be used to override the automatic adjus...

Page 9: ...line Note that this measurement is made intermittently for example every five or fifteen minutes and only the last known value is shown on the display The displayed value may be slightly different tha...

Page 10: ...display especially if the flow rate is variable Note also that the displayed value may be different that the one recorded in the data log or reported on the dashboard those values are averaged over th...

Page 11: ...r must be installed wired to the Well Bubbler and configured correctly to measure discharge pressure This value is not updated continuously and may be different from the one shown on a mechanical pres...

Page 12: ...nt transducer must be installed wired to the Well Bubbler and configured correctly to measure pump current This value is not updated continuously and may be different from the one shown on a clamp met...

Page 13: ...tory setting of 75 for 5 32 OD and 1 4 OD airlines higher values may be necessary when using 3 8 or larger galvanized sounding tube Reduce compressor power to 50 65 when using the Well Bubbler 10 120...

Page 14: ...nual compressor operation Use it to quickly verify that the compressor is operational or to manually purge the air line The default value of this parameter is OFF once turned ON the compressor will ru...

Page 15: ...to re start the pump as the water level recovers This relay is typically wired to a pump control panel HAND OFF AUTO switch Use the manual pump control menu to manually operate the relay and verify t...

Page 16: ...ement Set this parameter to ON to begin measuring the well level Set to OFF if automatic measurement is not needed and the Well Bubbler has good sunlight exposure or connected to a 24V supply to maint...

Page 17: ...5 seconds when using 5 32 OD or 1 4 OD airline A larger value up to 10 seconds may be required when using 3 8 or larger galvanized or stainless line Values between 1 and 3 seconds can be used when mea...

Page 18: ...ASUREMENT DELAY The Measurement Delay time should be set to the factory default value of 3 5 seconds when using 1 4 OD airline A larger value up to ten seconds should be used with 5 32 or smaller diam...

Page 19: ...models are five or fifteen minutes 10 300 models can sample between thirty and sixty minutes when using solar power only When powered from an external 24V supply all models can sample at up to five m...

Page 20: ...n the well is used to measure well level The Bubbler itself can be located as far away from the well as necessary without affecting measurement accuracy Enter the actual air line length to report wate...

Page 21: ...wired to a pump control panel HAND OFF AUTO switch Set the Start Pump Level to the well level at which the pump should safely start This value is typically determined by the net positive suction head...

Page 22: ...ically wired to a pump control panel HAND OFF AUTO switch Set the Stop Pump Level to the well level at which the pump should stop This value is typically determined by the net positive suction head NP...

Page 23: ...p when the water level is low and to re start the pump as the water level recovers This relay is typically wired to a pump control panel HAND OFF AUTO switch Set the Pump Restart Delay to a non zero v...

Page 24: ...metry Output feet Water Level feet mA 4 0 16 0 Telemetry Output feet Set this parameter to the maximum water level value you expect to measure or simply to the rating of the Bubbler itself For example...

Page 25: ...Well Bubbler set the Gallons Per Pulse to match the output of the flow meter itself This parameter must match the pulse output scaling of the flow meter exactly Only one flow meter can be wired to a...

Page 26: ...value to zero to disable the feature Only one flow meter can be wired to a Well Bubbler If both the pulse type flow meter scaling and the 4 20mA flow meter scaling are defined as non zero values the...

Page 27: ...here or set the value to zero to disable the feature If this 4 20mA sensor is configured and at least 4 0mA is not detected by the Well Bubbler the unit will display an error indicating that the sens...

Page 28: ...r set the parameter to zero to disable this feature If this 4 20mA sensor is configured and at least 4 0mA is not detected by the Well Bubbler the unit will display an error indicating that the sensor...

Page 29: ...ield is used to identify the well monitored by the Bubbler the Well ID is recorded with every data point allowing for convenient use of one Well Bubbler on multiple wells The Well ID is also reported...

Page 30: ...op the pump when the water level is low and to re start the pump as the water level recovers When the Well Bubbler relay is used to control a well pump this field should be set to Empty If the unit is...

Page 31: ...1 000 by default for measuring pure water The Well Bubbler can also be used to measure a variety of liquids such as acid fertilizer and sludge with different densities and specific gravity values The...

Page 32: ...section of the Well Bubbler website The user manual for the Manager software utility is also available for download along with the utility itself 8 Pin Connector 0 5 Vdc analog output 4 20 mA analog...

Reviews: