WWW.WELLBUBBLER.COM
CONFIGURATION: AIR LINE LENGTH
The air line length is measured from ground level (top of casing, sanitary seal, or
motor / gear head base), to the end located in the well, typically just above the
pump bowls.
The airline length between the discharge and the Well Bubbler does not matter,
and should not be entered here - only the length of air line actually in the well is
used to measure well level. The Bubbler itself can be located as far away from the
well as necessary, without affecting measurement accuracy.
Enter the actual air line length to report “water below ground” - this is the value
provided by a well sounder, and typically shown on pump tests, and well reports.
Enter zero to measure and report “water above the pump” - this option is used when
only the water column above the pump is of interest, or the air line length is
unknown. This value is also used when measuring tank and reservoir levels.
DRAWN BY: A. BUGROV
DATE: 02.20.2021