Document #: LIN_GO_SM_IMPLOPRO_S1600_INTL_4605727 – 9/20
n
Warning
Before removing or installing any component in the
Impinger Oven, be sure to disconnect all electrical
power and shut off gas supply.
Ignition Control (S/N L31478 and Below)
REPLACEMENT
Shut off power at main breaker:
1. Remove appropriate control box cover.
2. Remove front portion of relay by releasing tabs on side
pulling straight out (rocking motion).
3. Remove wires from plug-in terminal strip, note wire
numbers and location.
4. Remove two (2) screws from mounting bracket and
remove.
5. Reassemble in reverse order. Check system operation.
Ignition Control (S/N L31479 and Above)
REPLACEMENT
Shut off power at main breaker:
1. Remove appropriate control box cover.
2. Remove wires from control and mark for reassembly.
3. Remove one (1) mounting screw and remove ignition
control from gas valve.
4. Reassemble in reverse order and check system
operation.
Ignition Control (S/N 1803100100611 and
Above)
REPLACEMENT
Shut off power at main breaker:
1. Remove appropriate control box cover.
2. Remove plugs from control and mark for reassembly.
3. Remove two (2) mounting screws from control and
remove.
4. Reassemble in reverse order and check system
operation.
Air Pressure Switch
REPLACEMENT
Shut off power at main breaker:
1. Remove control panel top.
2. Disconnect wires from switch making note of wire
number and location for reinstallation.
3. Remove air tube from switch assembly.
4. Remove switch from wire hanger.
5. Install new switch in reverse, make sure air tube is not
blocked or misaligned.
NOTE: To adjust air pressure switch, remove cover from the
switch to expose adjusting screw. To increase sensitivity,
turn screw counter-clockwise; to decrease sensitivity, turn
screw clockwise. Check for proper line voltage switching
from NC to NO as the air pressure switch closes.
Conveyor Drive Motor
REPLACEMENT
Shut off power at main breaker:
1. Remove conveyor.
2. Remove control panel top and front cover.
3. Disconnect wiring from motor and mark for reassembly.
4. Remove sprocket from motor shaft.
5. Remove four (4) screws and remove conveyor motor
and mounting bracket.
6. Remove mounting bracket from conveyor motor
assembly.
7. Reassemble in reverse order.
Capacitor, Conveyor Motor
REPLACEMENT
Shut off power at main breaker:
1. Remove control box cover and front panel.
2. Discharge capacitor before removing wires. Mark wires
for reassembly.
3. Remove mounting screw and remove capacitor.
4. Reassemble in reverse order.
n
Warning
Capacitor has a stored charge, discharge before handling
or testing.
Section 7