22
Document #: LIN_GO_SM_IMPLOPRO_S1600_INTL_4605727 – 9/20
Maintenance
Section 4
Weekly Cleaning
1. Remove conveyor chain guard. Remove crumb pans
and take to the sink for cleaning.
2. Lift right end of conveyor and push in approximately 3”
(76 mm). Remove drive chain. (Split Belt models have
two drive chains to remove).
Conveyor
Drive
Sprocket
Drive Motor
Sprocket
Drive
Chain
3. Pull conveyor out the right end. Place on table or work
surface.
4. Inspect the chain for signs for wear. Replace if
necessary.
5. Verify the drive sprocket on the conveyor motor is
secure. Tighten if required.
6. Check conveyor motor fasteners to verify they are
secure. Tighten if required.
7. With the conveyor removed, screw out the four knobs
that hold the door and remove the door.
8. Remove the upper and lower finger assemblies and
take to the sink. Note any particular placement of
fingers that you may have, such as fully closed, half-
closed, or fully open, columnating plates.
Notice
Finger components MUST be placed back in the
correct positions. Failure to do so will cause the oven
to not cook correctly.
9. Disassemble fingers for cleaning.
10. Clean fingers and crumb trays with a mild detergert
solution, followed by a potable water rinse.
11. Clean the interior by sweeping up all loose particles,
then wash with a mild detergent solution and rinse
with clean water.
12. Clean the conveyor belt by wiping with a clean cloth or
use a scrub brush (Lincoln Catalog Number 369217).
13. Reassemble fingers. Insert columnating plate so the
step goes under the lip of the finger housing and the
plate lies flush with the housing side edge.
14. Install cover by sliding it on the small end.
15. Install top and bottom fingers in the oven by sliding
them over the plenum flange and setting on the front
bracket. BE SURE THAT THE FINGER SETS SQUARELY
OVER THE PLENUM FLANGES AND THE HOLES POINT IN
THE PROPER DIRECTION. Top fingers point down. Install
in the same position they were removed from.
Finger Housing
Finger Cover
Number
Stamped in
Panel