28
5.
Gently hammer out shaft and remove.
6.
Clean seal.
7.
Grease seal with food grade grease.
8.
Insert new shaft.
9.
Push new shaft past retraining ring groove and
install retaining ring.
10.
Tap shaft back to seat up against retaining ring.
11.
Complete reassembly by reinstalling bolt and
end cap.