background image

MODELS

:

MKET-12-T, MKET-20-T

Operators Manual

             

Installation

 &

 Operation

Electric Table Top Mixers

SE95015 Rev. 4

1333 East 179th St., Cleveland, Ohio, U.S.A. 44110

Phone: (216) 481-4900   Fax: (216) 481-3782

Visit our web site at www.clevelandrange.com

Cleveland

Enodis

For a complete Service Manual 
refer to www.clevelandrange.com

Summary of Contents for MKET-12-T

Page 1: ...n Operation Electric Table Top Mixers SE95015 Rev 4 1333 East 179th St Cleveland Ohio U S A 44110 Phone 216 481 4900 Fax 216 481 3782 Visit our web site at www clevelandrange com Cleveland Enodis For a complete Service Manual refer to www clevelandrange com ...

Page 2: ...s may be extremely hot Use protective equipment Keep appliance and area free and clear of combustibles Stand clear of product discharge path when discharging hot product Wear protective equipment when discharging hot product Do not lean on or place objects on kettle lip Do not attempt to operate this appliance during a power failure Keep clear of pressure relief discharge Keep hands away from movi...

Page 3: ... sign and date each form INSTALLATION The first installation step is to refer to the Specification Sheets or Specification Drawings for detailed clearance requirements of the kettle Next carefully cut open the shipping carton for easy removal of the kettle ASSEMBLY Table top models 12 gallon must be positioned on a firm level stand or existing counter top and bolted in place These models are suppl...

Page 4: ... the kettle on read the vacuum pressure gauge The gauge s needle should be in the green zone 3 Place the kettle s power ON OFF switch to the ON position 4 Turn the temperature control knob to 1 Min The green LED light should remain lit indicating the burner is lit until the set temperature is reached 124 F 50 C Then the green light will cycle on and off indicating the element is cycling on and off...

Page 5: ...nches of mercury 6 Pressure Relief Valve This valve is used to vent the kettle and in the unlikely event there is an excess steam build up in the jacket this valve opens automatically to relieve this pressure 7 Kettle Tilt Handle Used for tilting the kettle 8 Marine Lock Prevents unit from accidental tilting 9 Agitator Speed Control Knob This control allows the operator to select agitator speed in...

Page 6: ...icator Light Red 4 should not be lit when kettle is in the upright position during kettle operation This light indicates that the elements have been automatically shut off by the kettle s safety circuit It is however normal for the red light to come on when the kettle is in a tilted position 6 When cooking is completed place On Off Toggle Switch 1 to the OFF position 7 Pour the contents of the ket...

Page 7: ...ide to side play Lock should remain fully over stop pin when pushed to it s maximum side to side play Figure B 3 Check that the kettle when pushed fully upright moves the lock to a closed position To check this A Hold the latch firmly in the unlocked position while tilting the kettle back to an upright position B The kettle sidebox will force the lock into a new position C Hold the lock in this po...

Page 8: ...ure setting 6 Drain unit 7 Rinse interior thoroughly 8 If the unit is equipped with a Tangent Draw Off Valve clean as follows a Disassemble the draw off valve first by turning the valve knob counter clockwise then turning the large hex nut counter clockwise until the valve stem is free of the valve body b In a sink wash and rinse the inside of the valve body using a nylon brush c Use a nylon brush...

Page 9: ...ated Replace shoulder bolt and latch and tighten firmly 7 Replace lockwasher and locknut inside the console and tighten firmly 8 Test Marine Lock See Marine Lock Testing Procedure 9 Replace console cover Latch Shoulder Bolt Lockwasher Locknut Carefully apply locktight to the final two threads AGITATOR ASSEMBLY 1 Place the Kettle s On Off Toggle Switch 1 to the OFF position 2 Raise Mixer Bridge 11 ...

Page 10: ...ot be seen play it safe and use a soft cloth or plastic scouring pad 3 Use alkaline alkaline chlorinated or non chloride containing cleaners While many traditional cleaners are loaded with chlorides the industry is providing an ever increasing choice of non chloride cleaners If you are not sure of chloride content in the cleaner used contact your cleaner supplier If your present cleaner contains c...

Page 11: ...ghtness If loose apply lock tight and reinstall Check handle knob is on end of handle and firmly tightened If loose apply lock tight and reinstall PRESSURE GAUGE Check that the gauge does not have moisture on its inside face Replace if moisture is present Check that the gauge shows a vacuum needle is well into the Green zone when cold and shows between 25 40 psi when unit is hot If not follow Vacu...

Page 12: ...ith or bypassing controls is a very dangerous practice and unfortunately we have seen several cases of this Fol lowing is a short list of the most common and the most dangerous alterations performed on kettles Plug Tube diameter reduced Frozen stuck or plugged Plumbed to drain or water line 1 2 3 4 Incorrect Installations 1 Safety valve has plug threaded into the discharge opening prevent ing any ...

Page 13: ...afety thermostat probe is removed from tubing 3 Safety thermostat electrical connec tion is bypassed Low Water Level Probe Probe bypassed by running A an addi tional wire Probe properly attached 260º 270º MAXIMUM KETTLE TEMPERATURE 265º If maximum temperature is not in this range on empty kettle refer to the Calibrat ing Procedure in the unit s Installation Operation Service Manual Operating Therm...