![Weishaupt WRSol 1.0 Manual Download Page 90](http://html.mh-extra.com/html/weishaupt/wrsol-1-0/wrsol-1-0_manual_953375090.webp)
90
Technical data
9
9.1 Electrical data
Mains voltage__________________________230 V ± 10%
Mains frequency __________________________ 50-60 Hz
Consumption
________________________________7 VA
Voltage meas. circuit ______________12 V, insulated 4 KV
Breaking capacity outputs:
Electronic outputs ______________~230 V, 1 A, 50 Hz
Mechanical outputs __________~230 V, 6 (2) A, 50 Hz
External unit fuse ______________________________16 A
Internal unit fuse ________________________3.15 A slow
Type of protection __________________IP40 to EN 60529
Protection Class ____________II to EN 607300 if installed
correctly
Cables
Sensor cable length, cross section max. 100m, 0.75 mm
2
eBus __________________________________2 core Bus
Bus cable length, cross section ____max. 100m, 0.75 mm
2
9.2 Permissible ambient conditions
Temperature
Humidity
Requirements to
EMC
Low voltage
During operation
max. 85% rel. humidity
Guideline 89/336/EEC
Guideline 73/23/EEC
0°C…50°C
at 25°C
EN 50081-1
EN 60335
Transport/storage
no dew point
EN 50082-1
-20°C…+60°C
Micro-fuse 3.15 A slow
esc
200 mm
145 mm
49 mm
9.3 Dimensions