![Weishaupt WRSol 1.0 Manual Download Page 9](http://html.mh-extra.com/html/weishaupt/wrsol-1-0/wrsol-1-0_manual_953375009.webp)
9
3
Note:
Maximum loading for outputs 1 and 2 is
1 amp. Circuits with a higher current
consumption must be driven by an auxiliary
relay
.
If an auxiliary relay or valve for return
temperature increase is fitted to outputs 1
and 2, parameter
PS Speed Minimum
must
be set to 100%. Additionally
, an R
F
I
suppressor (-w- 7
01 8
9
0) must be connected
parallel to terminal 1/
N and/or 2/
N.
T
he internal unit fuse (F1) protects only the
outputs. T
he controller cannot be
de-energised via F1.
M
1~
(–)
(+)
M
1~
2
1
ϑ
ϑ
ϑ
ϑ
ϑ
ϑ
ϑ
N
PE
PE
PE
PE
PE
N
N
N
4
M
1~
PKS
/
PS
3
4N
L3
N
L
6
5
2
1
N
L P
E
N
23
0V 1/
N
/
P
E
5
0
Hz
F1
0
16
A
S1
L
M
1~
X2
X1
T
HR/
TK
R
16
15
PPS
/
PL
E
PPZ
TK
O
4
3
VI
Z
18
17
TB
Y/
TP
O
14
13
TP
U
/
TZW
12
11
TKW/
TSO/
TZ
U
10
9
T
SU/
TWW
/
TZO
8
7
TF
K/
TK2/
TKV/
T
SB/
TWT
6
5
MF
A
PWL
PZ
P
PFK
PKP
/
PPS
/
P
S2/
PWT
/
PWW
/
PZ
W
F1
3,1
5A
VB
Y/
VRA/
V
SB/
VS
P/
VU
P/
VP
O/
Wiring diagram WRSol 2.0
eBus
Pr
otective earthing
(Null potential
differ
ence) to loc
a
l
regulations
L
egend
TB
Y
Te
mperature sensor bypass (S
TF 222.2 -w- 6
6
0 228)
TF
K
Te
mperature sensor solid fuel boiler (S
TF 225 -w- 6
6
0 262)
TH
R
Temperature sensor heat circuit return (S
TF 222.2 -w- 6
6
0 228)
TK2
Temperature sensor collector 2 (S
TF 225 -w- 6
6
0 262)
TK
O
Temperature sensor collector (S
TF 225 -w- 6
6
0 262)
TK
R
Temperature sensor collector return (S
TF 222.2 -w- 6
6
0 228)
TKV
Te
mperature sensor collector supply (S
TF 222.2 -w- 6
6
0 228)
TKW
Te
mperature sensor D
HW cold (S
TF 222.2 -w- 6
6
0 228)
TP
O
Temperature sensor calorifier top (S
TF 222.2 -w- 6
6
0 228)
TP
U
Temperature sensor calorifier bottom (S
TF 222.2 -w- 6
6
0 228)
TS
B
Te
mperature sensor swimming pool (S
TF 222.2 -w- 6
6
0 228)
TSO
Temperature sensor t
a
nk top (S
TF 222.2 -w- 6
6
0 228)
TS
U
Temperature sensor t
ank bottom (S
TF 222.2 -w- 6
6
0 228)
TWT
Temperature sensor heat exc
hanger (S
TF 222.2 -w- 6
6
0 228)
TWW
Te
mperature sensor D
HW warm (S
TF 222.2 -w- 6
6
0 228)
TZO
Temperature sensor add. calorifier top (S
TF222.2 -w- 6
6
0 228)
TZ
U
Temperature sensor add. calorif. bottom S
TF222.2 -w- 6
6
0 228)
TZW
Temperature sensor circulation (S
TF 222.2 -w- 6
6
0 228)
VI
Z
V
olume impulse meter
Cable
blue
Cable
blue or grey
Cable
grey
Cable
grey
Cable
grey
Cable
grey
Cable
grey
Cable
grey
1
Internal unit fuse 3.15A medium time lag
F1
0
Pre-fusing max. 16A
S1
Emer
gency
switc
h
MF
A
Multi-function output (potential free)
PFK
Pump solid fuel boiler
PKP
Pump collector - calorifier
PKS
Pump collector - storage t
ank
PL
E
Pump Legionella
PPS
Pump Calorifier
PS
2
Pump Solar 2
PS
Pump Solar
PZ
W
Pump D
HW circulation
PWL
Pump D
H
W loading
PWT
Pump Heat exc
hanger
PWW
Pump D
H
W
PPZ
Pump calorifier - additional calorifier
PZ
P
Pump additional calorifier - calorifier
VB
Y
Bypass- valve
VP
O
Calorifier valve top
VRA
Return temperature increase valve
VS
B
Swimming pool valve
VS
P
Storage t
ank - calorifier valve
VU
P
Change-over calorifier valve