54
Parameter
6
Use:
The function of the solar controller can be stipulated using
selection menu point
S
Se
el
le
ec
ct
t
t
ty
yp
pe
e
o
of
f
o
op
pe
er
ra
at
ti
io
on
n
.
A
Au
ut
to
o
Automatic operation to the criteria set. From an energy
point of view the best type of operation.
M
Ma
an
nu
ua
al
l
Use for hydraulic commissioning and adjustment
of the solar system.
Output 1 is driven with 100%.
In manual operation
,
all outputs can be switched on and
off, or the speed control can be matched in 10 % steps
using
Test o
or
r
t
ta
ak
ke
e
o
ov
ve
er
r
o
ou
ut
tp
pu
ut
ts
s
.
O
Of
ff
f
The system is now switched off in accordance with the
software. The controller continues to carry voltage.
Interrupt the voltage supply to the controller prior to
carrying out service or repair work.
No frost protection
In types of operation
M
Ma
an
nu
ua
al
l
and
O
Of
ff
f
the
frost protection function is not longer active.
6.1 Select type of operation
ATTENTION
Select
type of
operation
esc
Auto
Manual
Off