background image

© 2016 Spectrum Brands, Inc. 

1.  Association Groups 

The lock supports 2 association groups.  Per Z-Wave Plus requirements, group 1 is 
assigned to the Lifeline group.  The Lifeline group supports the following unsolicited 
messages: 

Battery Report 

Door Lock Operation Report 

Notification Report 

Device Reset Locally Notification 

Group 2 is available for all Notification Reports and can be used to send notifications to 
at most 5 other nodes. 

2.  Configuration Parameters 

The Z-Wave door lock module supports the use of the configuration command class to 
provide advanced configuration of the door lock over the Z-Wave network.  This section 
describes the configuration parameters supported by the door lock. 

2.1  Configuration Parameters 1 through 30 

Configuration parameters 1 through 30 are a one byte field used to set the type of user for 
their corresponding user code.  The following table shows the valid values for user code 
types: 

Reserved 

Owner (Default) 

Reserved 

 

Guest (required for Year/Day schedules) 

!

Worker (required for week day schedules) 

" #

$%

Reserved 

$$

No User Code assigned 

Summary of Contents for Smartcode 5

Page 1: ...re to confirm that the hole in the door edge is 25 mm 1 in Measure to confirm that the door is between 35 and 44 mm 1 3 8 and 1 3 4 in thick A A C B D E B C D Is the semi circular hole of the latch centred in the door hole Is the door edge chiselled Install strike on the door frame Hold the latch in front of the door hole with the latch face flush against the door edge Adjust the latch face if nee...

Page 2: ... exterior lever Secure mounting plate with supplied screws Secure exterior lever Install spindle Install interior lever The small bolt of the latch should not enter the strike hole If it enters the strike hole reposition strike A A B B C C D D cable goes over latch Do not install battery pack into interior assembly yet Lever handle faces away from the latch Tighten pre installed set screw If latch...

Page 3: ...eping sound will only be heard if switch 3 on the lock interior is in the on positon See Switches and Status LED Colours on page 4 Mastercode For enhanced security a mastercode may be used when adding and deleting user codes For more information about the mastercode download the Programming and Troubleshooting Guide on the SmartCode 5 Lever page at www weiserlock com K K M H V 2x Tip You can press...

Page 4: ...trike Keypad flashes red 3 times with 3 beeps Unsuccessful programming Attempt programming procedure again One incorrect code entered Re enter code No user code programmed Program at least one user code Keypad flashes red 10 times with 10 beeps Low battery Replace batteries Lock beeps 2 times Programming timeout Attempt programming procedure again making sure not to pause for more than 5 seconds K...

Page 5: ...s 2 Configuration Parameters The Z Wave door lock module supports the use of the configuration command class to provide advanced configuration of the door lock over the Z Wave network This section describes the configuration parameters supported by the door lock 2 1 Configuration Parameters 1 through 30 Configuration parameters 1 through 30 are a one byte field used to set the type of user for the...

Page 6: ... on the type of schedule created Example If a weekday schedule is created for a user code the associated user code type will change to Worker If a year day schedule is created for a user code the associated user code type will change to Guest If a user code is of type Worker or Guest it must have an enabled entry schedule to have access to the lock If a user code of type Worker or Guest does not h...

Page 7: ...rogram the first four bytes of the SKU Setting parameter 34 will program the last 4 bytes of the SKU Most printable values are accepted for the set command When getting the SKU it must be done in two get commands one for each parameter The order of getting the SKU does not matter Getting parameter 33 will retrieve the first four bytes of the SKU Getting parameter 34 will retrieve the last 4 bytes ...

Page 8: ...k and will remove it from your smart home system It will not remove any anti theft settings Please use the local reset procedure only when the primary controller is missing or inoperable 5 1 Local 1 Remove battery pack and press the program button a few times to discharge 2 Press and hold the program button 3 Replace the battery pack 4 Continue holding the program button for 30 seconds until the l...

Reviews: