The door lock will only retain valid user code types (0x01, 0x03, and 0x04).  All other 
values will be ignored.  If a user code does not exist for the corresponding configuration 
parameter, the lock will report a value of 0xFF.  Any attempts to change the user code for 
a non-existent user will be ignored. 

A user code can only be set to one user code type at a time and, as indicated in the table 
above, user code types are associated with Schedule Entry Lock CC schedule types. This 
association between user code type and entry schedule type correlates to the Schedule 
Entry CC specification in that only one schedule type (week day or year day) may be 
associated with a user code at any time. Note: This does not prohibit a user code from 
having multiple schedules of the same type (Year Day or Week Day). 

By default all user codes are assigned type “Owner” when created. The type “Owner” 
designation indicates that that user code is active at all times. When an entry schedule is 
created for a user code, the associated user code type will automatically change 
depending on the type of schedule created. Example: If a weekday schedule is created for 
a user code the associated user code type will change to “Worker”. If a year day schedule 
is created for a user code the associated user code type will change to “Guest”. 

If a user code is of type “Worker” or “Guest” it must have an enabled entry schedule to 
have access to the lock. If a user code of type “Worker” or “Guest” does not have an 
enabled schedule or if there are no entry schedules defined the associated user code will 
not be given access by the lock. 

To provide the user code access to the lock the system must perform one of three actions: 

Re-enable the entry schedule for the user code that was previously disabled 

Create a new entry schedule for the user code 

Change the user code type to “Owner” 

WARNING

: If a user code is of type “Worker” or “Guest” and the system changes the 

user code type to “Owner” the associated user code will be given access to the lock 24/7 
regardless of any entry schedules defined for the user in the lock. 

2.2  Configuration Parameter 31 

Configuration parameter is a one byte read only bit mask that returns the state of the user 
accessible dipswitches on the rear panel of the door lock. 

The following table shows the definition for the bits being used in the returned value: 

Summary of Contents for Smartcode 5

Page 1: ...re to confirm that the hole in the door edge is 25 mm 1 in Measure to confirm that the door is between 35 and 44 mm 1 3 8 and 1 3 4 in thick A A C B D E B C D Is the semi circular hole of the latch centred in the door hole Is the door edge chiselled Install strike on the door frame Hold the latch in front of the door hole with the latch face flush against the door edge Adjust the latch face if nee...

Page 2: ... exterior lever Secure mounting plate with supplied screws Secure exterior lever Install spindle Install interior lever The small bolt of the latch should not enter the strike hole If it enters the strike hole reposition strike A A B B C C D D cable goes over latch Do not install battery pack into interior assembly yet Lever handle faces away from the latch Tighten pre installed set screw If latch...

Page 3: ...eping sound will only be heard if switch 3 on the lock interior is in the on positon See Switches and Status LED Colours on page 4 Mastercode For enhanced security a mastercode may be used when adding and deleting user codes For more information about the mastercode download the Programming and Troubleshooting Guide on the SmartCode 5 Lever page at www weiserlock com K K M H V 2x Tip You can press...

Page 4: ...trike Keypad flashes red 3 times with 3 beeps Unsuccessful programming Attempt programming procedure again One incorrect code entered Re enter code No user code programmed Program at least one user code Keypad flashes red 10 times with 10 beeps Low battery Replace batteries Lock beeps 2 times Programming timeout Attempt programming procedure again making sure not to pause for more than 5 seconds K...

Page 5: ...s 2 Configuration Parameters The Z Wave door lock module supports the use of the configuration command class to provide advanced configuration of the door lock over the Z Wave network This section describes the configuration parameters supported by the door lock 2 1 Configuration Parameters 1 through 30 Configuration parameters 1 through 30 are a one byte field used to set the type of user for the...

Page 6: ... on the type of schedule created Example If a weekday schedule is created for a user code the associated user code type will change to Worker If a year day schedule is created for a user code the associated user code type will change to Guest If a user code is of type Worker or Guest it must have an enabled entry schedule to have access to the lock If a user code of type Worker or Guest does not h...

Page 7: ...rogram the first four bytes of the SKU Setting parameter 34 will program the last 4 bytes of the SKU Most printable values are accepted for the set command When getting the SKU it must be done in two get commands one for each parameter The order of getting the SKU does not matter Getting parameter 33 will retrieve the first four bytes of the SKU Getting parameter 34 will retrieve the last 4 bytes ...

Page 8: ...k and will remove it from your smart home system It will not remove any anti theft settings Please use the local reset procedure only when the primary controller is missing or inoperable 5 1 Local 1 Remove battery pack and press the program button a few times to discharge 2 Press and hold the program button 3 Replace the battery pack 4 Continue holding the program button for 30 seconds until the l...

Reviews: