General

Intended use

The Tempura Quadra is an electric radiant heater which can only 
be used as such. The Tempura Quadra Universal design option is 
intended for wall and roof mounting. The Tempura Quadra Opal 
design option is intended exclusively installation on a weinor Opal 
Design II awning (without Valance). Misuse can lead to hazards and 
damage and is not permissible. Prohibited changes to the product 
will result in voiding of the guarantee claims. The Tempura Quadra 
is not to be used by people (children included) with limited physical, 
sensory or mental abilities or who lack the required experience and/
or knowledge unless they are accompanied by someone respon-
sible for their safety or have been properly instructed in the use 
of the Tempura Quadra. The Tempura Quadra does not feature an 
appliance for the control of the room temperature. There the Tem-
pura Quadra must not be used in small rooms that are occupied by 
people who cannot leave the room on their own, unless they are 
constantly monitored!

CE mark

weinor GmbH & Co. KG declares that the product is in compliance 
with the basic requirements and relevant provisions of the EN  
standards. This product meets the requirements of the guidelines 
and standards listed in the EC Declaration of Conformity.

Safety symbols 
 

Warning! Risk of electric shock

"Danger" of electric shock

Danger level  

III

Warning! Personal injury 

 

"Danger" of personal injury.

Danger level 

II

Caution! Product and property damage

Danger level 

I

 

Safety instructions 

  Warning! Risk of electric shock! 

•  Follow the warning instructions for the prevention of electrical 

shock!

•  Electrical installation or repairs may only be carried out by an 

authorised electrically skilled person according to VDE 100! 

•  Separate the electrical connections from the mains during the 

installation!

•  Only connect electrical termination to mains system with all-

pole disconnecting device and with min. 3 mm contact opening 
width!

•  Only connect the construction if indications on product relating 

to voltage, frequency and output match those of the power 
source!

•  Always disconnect the heater from the mains for disassembly or 

when replacing a tube (infrared lamp). 

•  Before cleaning, unplug the all-pole disconnector from the mains.
•  Do not let any liquids get into the heater.
•  It is not permitted to make any changes to the temperature-resis-

tant silicon lead, which is screwed onto the device.

•  If the power cord of the device has been damaged, it must be 

replaced by the manufacturer or the customer service or a similar 
qualified person, in order to avoid hazards.

  Caution! Danger of personal injury or burns! 

•  Note that the heater's installation height must be at least  

1.80 m*!

 

•  Pay attention to any children and vulnerable people present who 

cannot correctly assess the dangers of heat and hot  
product components.

•  Supervise any children present to make sure that they do  

not play with the device and keep unsupervised children 
(younger than 3 years old) away!

•  Children between the ages of 3 and 8 may only switch the device 

on and off if they are supervised, or if they have been instructed 
regarding the safe use of the device and have  
understood the resulting dangers (provided that the device has 
been placed and installed in its correct operating position). 

•  Children between the ages of 3 and 8 must not plug the plug con-

nector into the power socket, control the device, clean the device 
and/or perform the maintenance** !

• 

Caution! Acute risk of burns!

 Do not touch the heater housing 

as well as safety guard during operation and  
immediately after operation!

• 

Caution! Risk of fire and deflagration! 

Do not use any  

flammable cleaning agents (e.g. petrol, white spirit, etc.)

• 

Caution! 

Looking at the infrared lamp for too long may lead to 

eye damage! Avoid looking at the lamps when they are switched 
on.  

 Caution! Product and/or property damage may  

result from improper installation, operation and 
maintenance!

•  Use suitable installation and fitting materials (plugs, glue, etc.) 

corresponding to onsite conditions and loads to ensure  
proper mounting! 

•  Do not place and mount the heater underneath sockets,  

junction boxes etc.

•  Always mount the switch for turning the heater on and off in 

sight of the heater or label it clearly.

•  Do not mount the heater in the vicinity of flammable fabrics. 
•  Do not mount the heater on awnings **** with Valance or Valance 

Plus *** !

•  Make sure that all the materials around the heater have the requi-

red properties (as confirmed by the manufacturer's  
information or measurements)!

•  Never directly touch the infrared lamp. This shortens the lamp's 

operating life. Wipe the lamp with a soft cloth to completely 
remove any greasy residue if it has come into contact with skin!

•  Never leave the heater unattended during operation! 

Other information

•  Wood panelling on the wall and roof may become darker  

in colour due to heat from the device, even with proper  
installation.

•  The power cord (delivery status) is not suitable for permanent ins-

tallation as the PVC-coated lead is not designed for constant use.

•  Keep this document in a place where it is available at all times even 

after completing the installation! 

*)  

 If mounted on an awning, the awning headroom determines the heater's installation height.  
The heater's installation height must be at least 1.80 m*!

**)   With maintenance carried out by user.

***)    Exception: A control ensures that the awning is always extended first and then the Valance Plus 

and that the Valance Plus is always retracted first before the awning. In this way safety clearances 
are always adhered to.

****)   The fitting of Tempura Quadra to an awning refers to the weinor Opal Design II/LED.

Tempura Quadra  |   121070-0000 w  |  v3 |  2019-05-06  |  Montageanleitung  |  Montagehandleiding  |  Instructions for assembly  |  Instructions de montage

Summary of Contents for Tempura Quadra

Page 1: ...these instructions and observe their contents and warnings before using the equipment for the rst time Avant la premi re utilisation du produit veuillez lire cette notice et en respecter le contenu et...

Page 2: ...le 19 Wandanschlusspro l f r Halterung 260 Produkt bersicht und Lieferumfang Inhaltsverzeichnis Produkt bersicht Inhaltverzeichnis 2 Allgemeines 3 Technische Daten Ma e und Mindestabst nde 10 Montage...

Page 3: ...ie Gefahren von Hitzeentwicklung und hei er Produktkomponenten nicht richtig einsch tzen k nnen Beaufsichtigen Sie anwesende Kinder um sicherzustellen dass diese nicht mit dem Ger t spielen und halten...

Page 4: ...ngspro el met 2x rubberen banden 85x60 14 Armen universeel links rechts 15 Zeskantschroef M8 x 22 16 Voedingskabel met Hirschmannstekker STAS 3 Stak 3 17 Armen voor houder 260 links recht 18 Afdekpro...

Page 5: ...anwezige kinderen en hulpbehoevende personen die gevaren van hitteontwikkeli ng en hete productcomponenten niet goed kunnen inschatten Houd toezicht op aanwezige kinderen om er zeker van te zijn dat d...

Page 6: ...ket head screw 16 Power cord with Hirschmann plug STAS 3 Stak 3 17 Arm for left right 260 attachment 18 Faceplate for 260 attachment with 2 x cable sleeves 19 Wall gap sealing pro le for 260 attachmen...

Page 7: ...attention to any children and vulnerable people present who cannot correctly assess the dangers of heat and hot product components Supervise any children present to make sure that they do not play wit...

Page 8: ...cord mural avec 2 bandes en caoutchouc 85x60 14 Bras universels gauche droite 15 Vis t te hexagonale M8x22 16 C ble d alimentation r seau avec connecteur Hirschmann STAS 3 Stak 3 17 Bras pour xation 2...

Page 9: ...montage du chauffage soit d au moins 1 80 m Prot gez les enfants pr sents et personnes vuln rables qui n ont pas conscience vraiment des risques de g n ration de chaleur et d des composants br lants...

Page 10: ...el 404 x 130 x 170 Abmessungen Doorsneden en afmetingen Cross sections and dimensions Dimensions Tempura Quadra 404 x 130 x 90 Abmessungen Doorsneden en afmetingen Cross sections and dimensions Dimens...

Page 11: ...ues min 1800 min 1800 min 1800 1 5 min 1200 min 300 min 300 m i n 3 0 0 m i n 1 2 0 0 Mindestabst nde Sicherheitsbereiche Minimale afstanden veiligheidsgebieden Minimum distances safety areas Distance...

Page 12: ...aan een wand plafond Tempura Quadra Universeel B Montage aan een weinor Opal Design II zonnescherm C Montage met houder 260 aan een wand plafond Installation options A Installation on a wall roof Tem...

Page 13: ...n 1800 mm und Mindestabst nde beachten Attentie Let op horizontale uitlijning Gereduceerde levensduur van de buizen bij niet horizontale montage Minimale montagehoogte van 1800 mm en minimale afstande...

Page 14: ...le schade door onjuiste bevestiging Houd rekening met de bouwzijdige omstandigheden en maak gebruik van geschik te bevestigingsmiddelen Risk of personal injury and property damage if improperly tted...

Page 15: ...ericht wordt Houd rekening met de beperking van de hellingshoek alleen bij wandmontage Caution Product damage due to rainwater penetration if the heater mounted on the wall is tilted upwards Restrict...

Page 16: ...r uniquement par un monteur autoris Vorsicht Stromschlaggefahr Das Netzanschlusskabel ist eine hitzebest ndige Slikonschlauchleitung und darf nur durch eine gleiche Leitung ausgetauscht werden Voorzic...

Page 17: ...gedeelte van het apparaat komt te zitten Caution Damage to electrical com ponents due to rainwater penetration Mount the heater so that the rear cable outlet is at the top of the device Attention Domm...

Page 18: ...Opal Design II Montage van de Tempura Quadra op een weinor Opal Design II Installation of the Tempura Quadra on a weinor Opal Design II Montage du Tempura Quadra un weinor Opal Design II 1 2 Klemme n...

Page 19: ...Quadra Universal Achtung Beim Verschieben des Heizger tes auf ausreichende L nge der Netzanschlussleitung achten Attentie Let bij het verschuiven van de warmtestraler op voldoende lengte van de voedi...

Page 20: ...260 Installing the Tempura Quadra with 260 attachment Montage du Tempura Quadra avec Fixation 260 1 Achtung Die maximale Schrau benl nge bei Befestigung auf einer Holkammer beachten Attentie De maxim...

Page 21: ...cations techniques 4 5 2 0 4 5 2 0 2 3 Schwenkbereich Deckenmontage Wandmontage Draaibereik plafondmontage wandmontage Roof mounting wall mounting tilting range Plage d inclinaison Pose au plafond xat...

Page 22: ...jk is 1 Instructions for end users on the operation and functionality of the Tempura Quadra 2 Handover of the operation maintenance and installation instructions to the end user 3 Con rming the correc...

Page 23: ...safety guard during operation Prudence forte g n ration de chaleur Risque de br lure Ne touchez jamais le bo tier du dispositif de chauffage ainsi que la grille de protection pendant le fonctionnemen...

Page 24: ...istles Have heavy contamination removed by a professional Prudence risque de br lure Laissez refroidir le chauffage avant le nettoyage et coupez l alimentation en cou rant Nettoyer l appareil avec un...

Page 25: ...lie lich durch qualifizierte und ausgewiesene Fachkraft Voorzichtig Lichamelijk letsel en materi le schade Uitvoering onderhoudswerkzaamheden demontage montage en vervanging uitsluitend door gekwalifi...

Page 26: ...houden We reserve the right to make technical changes Sous r serve de modi cations techniques Tempura Quadra Tempura Quadra Universal 2 Tempura Quadra 121070 0000 w v3 2019 05 06 Montageanleitung Mont...

Page 27: ...de infraroodstraler nooit direct aan Gebruik handschoenen of een doek Verwijder vetresten met een zachte doek als er huidcontact geweest is Caution Never directly touch the infrared lamp Use gloves o...

Page 28: ...nical changes Sous r serve de modi cations techniques 2 x 4 x 4 x 2 x Tempura Quadra Tempura Quadra Universal click 16 16 15 17 Tempura Quadra Opal Tempura Quadra Universal 4 5 Tempura Quadra 121070 0...

Page 29: ...C ble en silicone r sistant aux temp ratures 3G1 5 mm 3G1 5 mm 1 2 3 1 2 3 PE N L 1 2 3 Schaltpl ne Aansluitschema s Circuit diagrams Schaltpl ne Warnung Stromschlaggefahr Elektrische Festinstallatio...

Page 30: ...ves r gionales nationales et internationales en vigueur au moment donn Veiller tenir compte de la recyclabilit des possibilit s de d montage et de tri des mat riaux et des groupes de composants de m m...

Page 31: ...in de door ons in verkeer gebrachte uitvoering voldoet aan de geldende fundamentele veiligheids en gezond heidsvoorschriften van de volgende EU richtlijnen Bij een niet met ons afgesproken wijziging...

Page 32: ...es to additional contents Renvoi d autres contenus Ausrichten Uitlijnen Adjust Orienter Markieren Markeren Select Marquer mm Messen Meten Measure Mesurer Bohren Boren Drill Percer Geeignete Befestigun...

Reviews: