Broadcast Notes:
When Broadcast message is sent from CL – AP the AP will always ACK the Client. When Broadcast
Message is sent from AP – CL no ACK will be sent back.
Management Frames:
Can be probes, Authenticate/ Associate messages, RTS Messages, Beacons, etc
Network Traffic Analysis
There are many devices and PC programs that will analyse performance of an Ethernet network. Freely available
programs such as Ethereal provide a simple cost effective means for more advanced analysis. By monitoring traffic on the
wired Ethernet, a better idea of regular traffic can be discovered.
Network Analysis programs make configuration of a filter for the WI-MOD-E a simple task.
4.6 - System Tools
The System Tools Page has a number of tools that help maintain the module firmware and configuration.
Configuration
Summary
This option is used to save all the different configuration pages onto one page,
for easy viewing. Page can also be saved (using the File/Save As function on
the drop File Menu) for future reference and emailing module configuration
details to Technical Support in the event of any configuration problems.
TCP Throughput Test
Performs a Throughput Test. See section 4.4 - ”Throughput Test” above for
details
Radio Path Test
Perform a Radio Path test without the use of a Laptop and get a visual
indication of RSSI and Throughput on the front panel LEDs.
Read Configuration
File
This option will show the module configuration in XML format. This file can be
saved for future reference.
Write Configuration
File
Any configuration XML files saved using the “Read Configuration” above can
be loaded back into the module
Firmware Upgrade
This option is used for firmware upgrades. Load the file using the “Browse”
button and when found press “Send” which will load the file into the module.
When completed press “Reset” Firmware upgrade can be done locally or
remotely via the radio.
System Log File
Shows an event log of the modules operation, used for diagnosing problems.
Page can be saved and emailed to WEIDMULLER if requested. “Clear System
Log” will clear out the log file and start fresh.
Reset
Resets the module
Factory Default
Configuration
Loads the Factory default configuration and resets. CAUTION – Doing this will
overwrite any current configuration