Quick Parameter Reference, Faults and Alarms
Crane | 8
Parameter
Description
Adjustable Range
Factory
Setting
User
Setting
Properties Groups Page
P1030
Speed Reference via Communication
Networks
0.0 to 500.0 Hz
0.0 Hz
SPLC
31
P1031
Speed Reference 1
0.0 to 500.0 Hz
6.0 Hz
SPLC
31
P1032
Speed Reference 2
0.0 to 500.0 Hz
60.0 Hz
SPLC
31
P1033
Speed Reference 3
0.0 to 500.0 Hz
0.0 Hz
SPLC
32
P1034
Speed Reference 4
0.0 to 500.0 Hz
0.0 Hz
SPLC
32
P1035
Speed Reference 5
0.0 to 500.0 Hz
0.0 Hz
SPLC
33
P1036
Dwell Time at Speed Reference 1
0.00
to 650.00 s
0.50 s
SPLC
33
P1037
Hoisting Current Threshold for
Lightweight Detection
0.0 to 200.0 A
10.0 A
SPLC
47
P1038
Lowering Current Threshold for
Lightweight Detection
0.0 to 200.0 A
7.0 A
SPLC
47
P1039
Speed Threshold for Lightweight
Detection Enabling
0.0 to 500.0 Hz
0.0 Hz
SPLC
47
P1041
Brake Release Frequency Threshold
0.0 to 500.0 Hz
4.0 Hz
SPLC
51
P1042
Load Hoisting Current Threshold
0.0
to
200.0 A
0.0 A
SPLC
51
P1043
Load Lowering Current Threshold
0.0
to
200.0 A
0.0 A
SPLC
51
P1044
Load Hoisting Torque Threshold
0.0 to 350.0 %
50.0 %
SPLC
51
P1045
Load Lowering Torque Threshold
0.0 to 350.0 %
30.0 %
SPLC
51
P1046
Brake Response Time to Release
0.00
to 650.00 s
0.10 s
SPLC
52
P1047
Inhibition of the Brake Closing during a
Hoisting/Lowering Command Transition
0 = Off
1 = On
0
SPLC
52
P1048
Brake Closing Frequency Threshold
0.5 to 500.0 Hz
2.5 Hz
SPLC
52
P1049
Delay Time for Brake Closing
0.00
to 650.00 s
0.00 s
SPLC
52
P1050
Time to Enable a new Command to
Brake Release
0.10
to 650.00 s
0.20 s
SPLC
53
P1051
Overweight Current Threshold in the
Minimum Speed
0.0 to 200.0 A
20.0 A
SPLC
60
P1052
Overweight Current Threshold in the
Maximum Speed
0.0 to 200.0 A
17.0 A
SPLC
60
P1053
Overweight Detection Delay Time
0.00
to 650.00 s
1.00 s
SPLC
61
P1054
Overweight Alarm (A770) Delay Time
0.00
to 650.00 s
0.50 s
SPLC
61
P1055
Load Detection Time
0.00
to 650.00 s
0.75 s
SPLC
65
P1056
Slack Cable Alarm (A772) Delay Time
0.00
to 650.00 s
0.50 s
SPLC
66
P1057
Slack Cable Fault (F773) Delay Time
0.00
to 650.00 s
0.00 s
SPLC
66
P1058
Number of Consecutive Alarms for
Improper Fault (F777)
0 to 10
3
SPLC
69
P1059
Period of Time for Improper Fault (F777)
0 to 65000 s
120 s
SPLC
69
Summary of Contents for Crane CFW500 series