Quick Parameter Reference, Faults and Alarms
Crane | 7
QUICK PARAMETER REFERENCE, FAULTS AND ALARMS
CRANE VERTICAL MOTION
Parameter
Description
Adjustable Range
Factory
Setting
User
Setting
Properties Groups Page
P1010
Crane Vertical Motion Version
0.00 to 10.00
ro
SPLC
70
P1011
Last Alarm
0 to 999
ro
SPLC
70
P1014
Second Alarm
0 to 999
ro
SPLC
70
P1017
Third Alarm
0 to 999
ro
SPLC
70
P1020
Crane Vertical Motion Status Word 1
Bit 0 = General Enabled
Bit 1 = Running (RUN)
Bit 2 = Rotation Direction
Bit 3 = LOC / REM
Bit 4 = Fault Condition
Bit 5 = Undervoltage
Bit 6 = Alarm Condition
Bit 7 = Hoisting Command
Bit 8 = Lowering Command
Bit 9 = Brake Release Command
Bit 10 to 15 = Reserved
ro
SPLC
71
P1021
Crane Vertical Motion Status Word 2
Bit 0 = Lightweight Operation
Bit 1 = Coast to Stop
Bit 2 = Fast Stop
Bit 3 = Emergency Stop
Bit 4 = Stop by Simultaneous Commands
Bit 5 = Hoisting Slowdown
Bit 6 = Reserved
Bit 7 = Reserved
Bit 8 = Programming Error Release Brake
Bit 9 = Overweight
Bit 10 = Slack Cable Alarm
Bit 11 = Slack Cable Fault
Bit 12 = Inverter in Torque Limit
Bit 13 = Improper Operation
Bit 14 = Reserved
Bit 15 = Reserved
ro
SPLC
71
P1022
Communication Network Control Word
Bit 0 = Load Hoisting
Bit 1 = Load Lowering
Bit 2 to 15 = Reserved
0
rw
SPLC
33
P1023
Speed Reference Control Configuration
0 = Speed Reference via Electronic
Potentiometer (EP)
1 = One Speed Reference via Digital Input
DI4
2 = Two Speed References via Digital Input
DI4
3 = Three Speed References via Digital
Input DI4 and DI5
4 = Four Speed References via Digital Input
DI4 and DI5
5 = Five Speed References via Digital Input
DI4, DI5 and DI6
6 = Speed Reference via Analog Input AI1
(Step Less)
7 = Speed Reference via Communication
Networks
2
cfg
SPLC
30
P1024
Enable use of a Filter in the Hoisting and
Lowering Commands
0.00 to 15.00 s
0.10 s
SPLC
27
P1025
Limit Switches Configuration
0 = Without Limit Switches
1 = Hoisting Slowdown via DI3
2 = Hoisting Slowdown via DI7
0
cfg
SPLC
34
P1026
Motor Rotation Direction Inversion
0 = Off
1 = On
0
cfg
SPLC
27
P1027
Motor Demagnetization Time
0 to 65000 s
600 s
SPLC
27
P1028
Speed Hysteresis for Inverter in Torque
Limit Detection
0.0 to 50.0 %
7.5 %
SPLC
68
P1029
Inverter in Torque Limit Fault (F775) Delay
Time
0.00 to 650.00 s
0.75 s
SPLC
69