Parameters Description
Crane | 33
P1035 – Speed Reference 5
Adjustable
0.0 to 500.0 Hz
Factory Setting:
P1023 = 0: 0.0 Hz
Range:
P1023 = 1: 0.0 Hz
P1023 = 2: 0.0 Hz
P1023 = 3: 0.0 Hz
P1023 = 4: 0.0 Hz
P1023 = 5: 60.0 Hz
P1023 = 6: 0.0 Hz
P1023 = 7: 0.0 Hz
Proprieties:
Access groups via HMI:
SPLC
Description:
This parameter has different functions according to the speed reference control configuration:
■
P1023 = 0, 1, 2, 3, 4, 6 or 7, the parameter does not have a specific function for the crane.
■
P1023 = 5, it defines the value of the 5th speed reference for the crane.
P1036 – Dwell Time at Speed Reference 1
Adjustable
0.00 to 650.00 s
Factory Setting:
0.50 s
Range:
Proprieties:
Access groups via HMI:
SPLC
Description:
This parameter defines the crane dwell time with the speed reference 1 after the brake release. I.e., maintains
the speed reference 1 for a while even if another speed has been selected by the user.
3.6 CONTROL WORD
P1022 – Communication Network Control Word
Adjustable
0000h to FFFFh
Factory Setting:
0000h
Range:
Proprieties:
Access groups via HMI:
SPLC
Description:
This parameter defines the control word for the Crane when the speed reference control via communication
networks has been selected (P1023 = 7).
Each bit of this word represents a command that can be executed via communication networks.
Table 3.3 – Description of the communication network control word
Bits
15 to 2
1
0
Function
R
eser
ved
Load
Lo
w
er
ing
/R
ev
er
se
Load
Ho
is
tin
g/
Fo
rw
ar
d
Bits
Values
Bit 0
Load Hoisting/Forward
0: It removes the load hoisting/forward command.
1: It executes the load hoisting/forward command.
Bit 1
Load Lowering/Reverse
0: It removes the load lowering/reverse command.
1: It executes the load lowering/reverse command.
Bits 2 to 15
Reserved.