Parameters Description
Crane | 31
P1030 – Speed Reference via Communication Networks
Adjustable
0.0 to 500.0 Hz
Factory Setting:
P1023 = 0: 0.0 Hz
Range:
P1023 = 1: 0.0 Hz
P1023 = 2: 0.0 Hz
P1023 = 3: 0.0 Hz
P1023 = 4: 0.0 Hz
P1023 = 5: 0.0 Hz
P1023 = 6: 0.0 Hz
P1023 = 7: 6.0 Hz
Proprieties:
Access groups via HMI:
SPLC
Description:
This parameter has different functions according to the speed reference control configuration:
■
P1023 = 0, 1, 2, 3, 4, 5 or 6, the parameter does not have a specific function for the crane.
■
P1023 = 7, it defines the speed reference value via communication networks for the crane.
P1031 – Speed Reference 1
Adjustable
0.0 to 500.0 Hz
Factory Setting:
P1023 = 0: 6.0 Hz
Range:
P1023 = 1: 60.0 Hz
P1023 = 2: 6.0 Hz
P1023 = 3: 6.0 Hz
P1023 = 4: 6.0 Hz
P1023 = 5: 6.0 Hz
P1023 = 6: 6.0 Hz
P1023 = 7: 0.0 Hz
Proprieties:
Access groups via HMI:
SPLC
Description:
This parameter has different functions according to the speed reference control configuration:
■
P1023 = 0, it defines the minimum speed reference value for the crane. In other words, it is the initial speed
reference value when the load hoisting/forward or lowering/reverse command is executed. This value can be
subsequently incremented through the “acceleration” command via the digital input DI4.
■
P1023 = 1, 2, 3, 4 or 5, it defines the value of the 1st speed reference for the crane.
■
P1023 = 6, it defines the minimum speed reference value for the crane. In other words, it is the initial speed
reference value when the value read at the analog input is 0 V, 0 mA or 4 mA.
■
P1023 = 7, the parameter does not have a specific function for the crane.
P1032 – Speed Reference 2
Adjustable
0.0 to 500.0 Hz
Factory Setting:
P1023 = 0: 60.0 Hz
Range:
P1023 = 1: 0.0 Hz
P1023 = 2: 60.0 Hz
P1023 = 3: 30.0 Hz
P1023 = 4: 20.0 Hz
P1023 = 5: 15.0 Hz
P1023 = 6: 60.0 Hz
P1023 = 7: 0.0 Hz
Proprieties:
Access groups via HMI:
SPLC