Programming
E0129: Ethernet Offline.
E0130: Ethernet interface access error.
E0131: Timeout on Modbus communication.
The actions described in this parameter are executed by means of the automatic writing of the selected actions in
the respective bits of the interface control words. Therefore, in order that the commands written in this parameter
be effective, it is necessary that the device be programmed to be controlled via the used network interface. This
programming is achieved by means of parameters P0220 to P0232.
P0680 – STATUS WORD
Range:
0000h ... FFFFh
Default:
-
Properties:
RO
Description:
It allows the device status monitoring. Each bit represents a specific status:
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Function
Reserved
Digital
Output
O4
Status
Digital
Output
O3
Status
Digital
O
utput
O2
Status
Digital
Output
O1
Status
Digital
Input
I16
Status
Digital
Input
I15
Status
Digital
Input
I14
Status
Digital
Input
I13
Status
Digital
In
put
I12
Status
Digital
Input
I11
Status
Remote
Mode
Motor
On
Alarm/Fault
Trip
Err
or
SRW01-ETH | 13