background image

PNOZ pps1p

Operating Manual 20675-EN-03

}

Safety relays

Summary of Contents for PNOZ pps1p

Page 1: ...PNOZ pps1p Operating Manual 20675 EN 03 Safety relays ...

Page 2: ...cumentation will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Internet on the Pilz homepage Pilz PIT PMI PNOZ Primo PSEN PSS PVIS SafetyBUS p SafetyEYE SafetyNET p the spirit of safety are registered and protected trademarks of Pilz GmbH Co KG in some countries SD mea...

Page 3: ... Intended use 5 Safety regulations 5 Use of qualified personnel 5 Warranty and liability 6 Disposal 6 Unit features 6 Block diagram 7 Function Description 7 Installation 7 Wiring 9 Preparing for operation 9 Operation 9 Status indicators 9 Faults Interference 10 Dimensions in mm 10 Technical details 10 Order reference 12 EC declaration of conformity 12 ...

Page 4: ...ularly important is identified as follows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates preventive measures that can be taken WARNING This warning must be heeded It warns of a hazardous situation that could lead to serious injury and death and indicates preventive measures that can be taken CAUTION This...

Page 5: ... other environments measures should be taken to comply with the applicable standards and directives for the respective installation site with regard to in terference Safety regulations Use of qualified personnel The products may only be assembled installed programmed commissioned operated maintained and decommissioned by competent persons A competent person is someone who because of their training...

Page 6: ...the manual Operating personnel are not suitably qualified Any type of modification has been made e g exchanging components on the PCB boards soldering work etc Disposal When decommissioning please comply with local regulations regarding the disposal of electronic devices e g Electrical and Electronic Equipment Act Unit features Connection options for 1 base unit Maximum 4 expansion modules LED ind...

Page 7: ...r 24 V DC The output voltage is fed to the terminals 0 V and 24 V for measuring purposes Installation The unit should be installed in a control cabinet with a protection type of at least IP54 Use the notches on the rear of the unit to attach it to a DIN rail Fit the unit to a horizontal DIN rail If other mounting positions are used the switching capability values stated in the technical details ca...

Page 8: ... unit 4 expansion modules 1 power supply unit Power supply PNOZ pps1p Base unit Expansion module 1 Expansion module 4 95579 Terminator Order no 779120 95579 Terminator Order no 779120 95425 Jumper Order no 774639 WARNING Risk of electrocution When voltage is applied contact with live components could result in seri ous or even fatal injury from an electric shock The plug in connection terminals sh...

Page 9: ...nnect an external supply voltage to terminals A1 and A2 of the base unit Use copper wire that can withstand 60 75 C Ensure the wiring and EMC requirements of IEC 60204 1 are met Preparing for operation Supply voltage AC DC A1 A2 L1 N FE Operation NOTICE The safety function should be checked after initial commissioning and each time the plant machine is changed The safety functions may only be chec...

Page 10: ...provals CCC CE EAC Eurasian TÜV cULus Listed Electrical data Supply voltage Voltage 100 240 V Kind AC Voltage tolerance 15 10 Output of external power supply AC 30 VA Frequency range AC 50 60 Hz Duty cycle 100 Output voltage Voltage 19 V 24 V Kind DC Output power 15 W Times Supply interruption before de energisation 20 ms Environmental data Climatic suitability EN 60068 2 78 Ambient temperature Te...

Page 11: ...e g control cabinet IP54 Housing IP40 Terminals IP20 Mechanical data Mounting position Horizontal on top hat rail Material Bottom PPO UL 94 V0 Front ABS UL 94 V0 Top ABS UL 94 V0 Connection type Screw terminal Mounting type plug in Conductor cross section with screw terminals 1 core flexible 0 2 2 5 mm 24 14 AWG 2 core with the same cross section flexible with crimp connectors no plastic sleeve 0 ...

Page 12: ...Screw terminals 773 200 EC declaration of conformity This product these products meet the requirements of the directive 2006 42 EC for ma chinery of the European Parliament and of the Council The complete EC Declaration of Conformity is available on the Internet at www pilz com support downloads Representative Norbert Fröhlich Pilz GmbH Co KG Felix Wankel Str 2 73760 Ost fildern Germany ...

Page 13: ...ET p the spirit of safety are registered and protected trademarks of Pilz GmbH Co KG in some countries We would point out that product features may vary from the details stated in this document depending on the status at the time of publication and the scope of the equipment We accept no responsibility for the validity accuracy and entirety of the text and graphics presented in this information Pl...