Chapter 7
Adjustment and initial operation
40001136 Geset 125
Version: 30.07.14
Page 41 of 57
GB
Adjust peeler plate
The peeler plate of top side labeling has to be adjusted on distance and position to the
product. Use the adjusting device of the labeler.
Information on adjustment of peeler plate
The peeler plate has to be adjusted on a distance of approx. 1-3 mm to the product (no
product contact) via traverse adjustment of the labeler (no product contact). The peeler
plate should be installed in an angle of 15°-30° to product.
The required label position on the product is adjusted by lateral adjustment of the labeler.
Fig. 7-8: Adjust peeler plate
No.
Description
1
CRANK FOR HEIGHT ADJUSTMENT
2
CRANK FOR SIDE ADJUSTMENT
3
CLAMPING FOR ANGLE ADJUSTMENT
4
PEELER PLATE
5
SAMPLE PRODUCT
Requirements
¥
Side guidance is correctly adjusted (s. page 37).
¥
Labeler is switched on and ready.
¥
One or more sample products.
¥
No transportation of products.