18
SEAR STATION
®
IGNITION & USAGE
1
7
5
2
6
4
3
The grills illustrated
in this Owner’s Guide
may vary slightly from
the model purchased.
2
6
ARRÊTÉ
APAGADO
OFF
ON
SEAR STATION
®
BURNER IGNITION
Summary lighting instructions are inside the left-hand cabinet door.
m
DANGER
Failure to open the lid while igniting the grill’s burners, or not
waiting five minutes to allow the gas to clear if the grill does
not light, may result in an explosive flame-up which can cause
serious bodily injury or death.
The Sear Station
®
burner has an on or off control setting. To ignite the Sear Station
®
burner, you must first ignite the two adjacent main burners.
Adjacent Main Burner Snap Ignition
Note: Each main burner control knob snap igniter creates a spark from the igniter electrode
to the burner lighting tube. You generate the energy for the spark by pushing in the control
knob and turning it to START/HI. This will ignite each individual burner.
m
WARNING: Check hose before each use of grill for nicks,
cracking, abrasions or cuts. If the hose is found to be damaged
in any way, do not use the grill. Replace using only Weber
®
authorized replacement hose. Contact the Customer Service
Representative in your area using the contact information on
our web site.
Log onto www.weber.com.
A) Open the lid (1).
B) Make sure all burner control knobs are turned off (2). (Push control knob in and
turn it clockwise to ensure that it is in the OFF position.)
C) Turn on the gas supply at source (3).
m
WARNING: Do not lean over the open grill.
D) Ignite each main burner that is adjacent to the Sear Station
®
(4). Push the control
knob in and turn it to START/HI until you hear the igniter snap; continue to hold
control knob in for two seconds. This action will spark the igniter, the burner
lighting tube, and then main burner.
E) Check that the burner is lit by looking through the cooking grates (5). You should
see a flame. If burner does not light on first try, push control knob in and turn it to
OFF. Repeat lighting procedure a second time.
Sear Station
®
Burner Lighting:
Ignition by an Adjacent Ignited Main Burner
F) Turn Sear Station
®
burner control knob to the ON position (6).
G) Verify burner ignition by visual inspection of a flame (7).
m
WARNING: If ignition does not occur in five seconds, turn
burner control OFF, wait five minutes, and repeat steps F
& G, or see “SEAR STATION
®
BURNER MANUAL IGNITION”
instructions.
m
WARNING: If the burner still does not light, turn the burner
control knob to OFF and wait five minutes to let the gas clear
before you try again or try to light with a match.
Note: See “MAINTENANCE” for burner removal and cleaning
procedure.
◆
TO EXTINGUISH
Push in and turn each burner control knob clockwise to OFF position. Turn gas supply
off at the source.
◆
Summary of Contents for 59865
Page 66: ...66 MEMO...
Page 99: ...WWW WEBER COM 99 MEMO...
Page 111: ...WWW WEBER COM 11 1 2 460 660 ASSEMBLY ENSAMBLAJE ASSEMBLAGE...
Page 113: ...WWW WEBER COM 13 5 6 ASSEMBLY ENSAMBLAJE ASSEMBLAGE...
Page 114: ...14 7 8 ASSEMBLY ENSAMBLAJE ASSEMBLAGE...
Page 115: ...WWW WEBER COM 15 9 10 ASSEMBLY ENSAMBLAJE ASSEMBLAGE...
Page 118: ...18 15 16 ASSEMBLY ENSAMBLAJE ASSEMBLAGE...
Page 123: ...WWW WEBER COM 23 25 26 ASSEMBLY ENSAMBLAJE ASSEMBLAGE...
Page 125: ...WWW WEBER COM 25 1 2 28 ASSEMBLY ENSAMBLAJE ASSEMBLAGE...
Page 140: ...40 MEMO...
Page 155: ......
Page 156: ......
Page 174: ...WWW WEBER COM 11 1 2 460 660 ASSEMBLY ENSAMBLAJE ASSEMBLAGE...
Page 176: ...WWW WEBER COM 13 5 6 ASSEMBLY ENSAMBLAJE ASSEMBLAGE...
Page 177: ...14 7 8 ASSEMBLY ENSAMBLAJE ASSEMBLAGE...
Page 178: ...WWW WEBER COM 15 9 10 ASSEMBLY ENSAMBLAJE ASSEMBLAGE...
Page 181: ...18 15 16 ASSEMBLY ENSAMBLAJE ASSEMBLAGE...
Page 186: ...WWW WEBER COM 23 25 26 ASSEMBLY ENSAMBLAJE ASSEMBLAGE...
Page 188: ...WWW WEBER COM 25 1 2 28 ASSEMBLY ENSAMBLAJE ASSEMBLAGE...
Page 203: ...40 MEMO...