/CMD 

Read/Write/Delete  Contains the commands. 

The command file has the following format:  

“<

uid

>_cmd.csv”

 

/ALARM 

Write 

Contains the alarms. 
The alarm file name is in the following format:  

“<

uid

>_AL_<

timestamp

>.csv.gz” 

 

/LOG 

Write 

Contains the log and debug files. 
The log file has the following format:  

“<

uid

>_LOG_<

timestamp

>.log.gz”

 

The debug file has the following format:  

“<

uid

>_SYSTEME_<

timestamp

>.tar.gz”

 

/BIN 

Read 

Contains the update files. 
The  concentrator  update  has  the  following 
format: 

“wgapp_

<version>.spm

 

 
Where: 

 

<uid>

: Concentrator identifier (site) 

 

<

timestamp

>: The 

timestamp format is “YYMMDD_HHMMSS” so that an alphabetical 

sort of the directory gives the chronological order 

 

<

interface

>: the interface name from a defined list (

see section 3.1.2.2.2: 

Definition 

file content

”)

 

 

<

comment

>: free user field 

 

<

version

>: update version number. 

 

The data, alarm and log files are compressed to the Gzip format “.gz”.

 

The  minimum access  rights to  the different directories  must  be defined as  specified  in  the 
table above. 
 

 

If the directories are not created at the concentrator connection, or if the rights are 
not sufficient to upload or download files, contact the server administrator. 

 

 

All  files  exchanged between  the  concentrator  and the  server  must  have standard 
UTF-8 encoding.  

 
 

Operation: 

If  the  “FTP_TwoStepsSendingDisabled”  or  “FTP2_TwoStepsSendingDisabled”  parameter 
equals “1”, the concentrator uploads the files to the FTP server 

using a 2 step process: 

1.

 

At the start of the transfer the file has an additional ".tmp” extension.

 

2.

 

When the file transfer is complete, it is renamed by removing the ".tmp" extension. 

 

Summary of Contents for WebdynSunPM

Page 1: ...WebdynSunPM Supervision gateway for photovoltaic installations USER MANUAL...

Page 2: ...all mounting 21 Interface description 22 2 4 1 Product power supply 22 2 4 1 1 External power supply 22 2 4 1 2 Battery 23 2 4 2 Cellular Network 23 2 4 2 1 Antenna 23 2 4 2 2 SIM card 24 2 4 3 Indica...

Page 3: ...ing a device 85 3 2 1 2 4 Modifying the input output configuration 86 3 2 1 2 5 Duplicating a device 89 3 2 2 Settings 90 3 2 2 1 Concentrator 90 3 2 2 2 Serial 91 3 2 2 3 Networks 93 3 2 2 4 Modem 95...

Page 4: ...6 4 1 5 CMD commands 138 4 1 6 SCRIPTS 138 4 1 7 BIN update 138 4 1 8 LOG 139 4 1 8 1 Connection logs 139 4 1 8 2 Script logs 142 4 1 8 3 SunSpec detection logs 142 4 1 8 4 System logs 144 The MQTT MQ...

Page 5: ...d values Open text format representing tabulated data in the form of values separated by semi colons This format makes it easy to use data with spreadsheet software such as Excel DNS Domain Name Syste...

Page 6: ...strial control equipment in Europe RSSI Received Signal Strength Indication Reception power level measurement of a signal issued by a radio antenna RTU RTU mode is an RS422 485 hard wired bus for Modb...

Page 7: ...uting TIC Customer remote information Digital data output from ERDF meters that permanently broadcasts the managed contractual parameters as well as the consumption magnitudes measured by the meter UD...

Page 8: ...stics Section 6 FAQ Scope This technical description is valid for WebdynSunPM concentrators as from hardware version V1 and software version V3 0 0 Target group This guide is intended for all people i...

Page 9: ...9 USER MANUAL WebdynSunPM Version 2 05 pr liminaire 1 Presentation...

Page 10: ...principle The WebdynSunPM concentrator can be fully integrated into photovoltaic installations Devices such as inverters sensors pyranometers temperature sensors etc meters displays circuit breakers...

Page 11: ...The interfaces Devices WebdynSunPM Operation 0 1 5 3 0 Sensors Meters Inverters Displays Circuit breakers Relays etc Web Server Scripts Data management Troubleshooting Text message Server MQTT Server...

Page 12: ...g inputs 1 Relay output Indicators Power 12 24 V power supply status Activity Product status Serial1 Serial2 Serial3 Tx Data sent on the RS485 RS422 serial port Rx Data received on the RS485 RS422 ser...

Page 13: ...cal interface Specifications SMA net RS485 RS422 2 wires 100 max Modbus TCP Ethernet 254 max Modbus RTU RS485 RS422 2 wires or 4 wires 247 max Power One Aurora RS485 RS422 2 wires 100 max TIC USB cabl...

Page 14: ...F inputs AC1301 01 Single phase electricity meter AC1301 02 Single phase electricity meter with relay AC1302 01 Three phase electricity meter AC1302 02 Three phase electricity meter with relay AC1001...

Page 15: ...he waste must be collected via a specific channel and must not be disposed of as household waste Symbol indicating that the product must be recycled 1 6 2 Technical specifications Specifications Descr...

Page 16: ...S 1 6 3 Software specifications Specifications Protocols Formats Embedded server HTTP Server communication protocol IS FTP SFTP MQTT MQTTS generic and compatible with AWS IoT Azure IoT and Google Clou...

Page 17: ...to gently clean and wipe the surfaces Never use aggressive chemical agents or solvents that could alter the plastic material or corrode the metal parts It is essential to leave a 20 cm empty space ar...

Page 18: ...18 USER MANUAL WebdynSunPM Version 2 05 pr liminaire 2 Installation and Maintenance...

Page 19: ...d below for any intervention on site and to install the product To have a SIM card with an activated M2M subscription data and text messages optional and knowledge of the supplier s APN The SIM card c...

Page 20: ...s accessible on the top of the product The product CE label on the back of the box Commercial reference Product serial number Date of manufacture WG0517 A01 WW Y Y MAC 00 05 F3 00 00 00 WFFVVAAHHHHHH...

Page 21: ...oftware version is available on the Home tab See section3 2 Embedded web interface Assembly 2 3 1 Opening closing the box Users must not open the product It must be returned to after sales for all wor...

Page 22: ...Pivot the concentrator downwards Before fixing or removing the concentrator make sure To cut the power supply to the equipment Remove the antenna taped to the back of the box Interface description 2 4...

Page 23: ...lure fault and switch the product to safety mode until the power supply returns The battery recharges on the concentrator s external power supply The battery may not have time to recharge if the conce...

Page 24: ...rs must make sure their installation using remote antennas meets applicable EMC standards 2 4 2 2 SIM card To use the 2G or 3G modem connection and allow the concentrator to communicate with the remot...

Page 25: ...ition To remove the SIM card from the concentrator briefly press the end of the SIM card protruding from the product until it clicks then release it You can then recover the SIM card Webdyn does not s...

Page 26: ...been shut down it can be rebooted by simply pressing the Power button 2 4 3 2 Factory Reset button The Factory Reset button is used to recover the product in any situation loss of IP address loss of...

Page 27: ...efault operation During a long press on the Power button the Activity indicator will flash every second to help the user complete an action 2 4 3 5 Serial LED The bus has 3 RS485 422 serial buses and...

Page 28: ...es followed by a 1 second pause Indicates the modem signal level by flashing 1 Unstable 2 Limit 3 Correct 4 Good 5 Excellent green Fast flashing FTP connection in progress orange Slow flashing NTP syn...

Page 29: ...These Ethernet interfaces allow the concentrator to be part of 2 different Ethernet networks to communicate with local IP devices belonging to 2 separate networks or to communicate with the IS using...

Page 30: ...interface The WebdynSunPM concentrator has 3 RS485 RS422 serial ports marked Serial on the bottom of the product which are only used for modbus in RTU mode This interface is Half Duplex 2 wires and Fu...

Page 31: ...ned or shielded twisted pair per pair see above cable type for RS485 bus connection The cable screen or shielding must be connected to the concentrator box earth and not to the 0 V only connect one en...

Page 32: ...carries data sent from the concentrator to the device and the other pair the data sent from the device to the concentrator Several systems can be connected to the bus as shown on the following figure...

Page 33: ...m is balanced If the common conductor is not installed between all the devices they must be properly grounded in compliance with the manufacturer recommendations for each network device This requireme...

Page 34: ...put is equal to the concentrator s power supply voltage The earth on each analog terminal block is common Each analog input can be software configured to 0 10V or 4 20mA The concentrators analog digit...

Page 35: ...he sensors must not exceed 7 watts 2 4 7 2 Digital ON OFF S0 pulsed inputs The WebdynSunPM concentrator has 3 inputs that can be configured to ON OFF mode or S0 pulsed mode pulse counting These inputs...

Page 36: ...onto the digital inputs In ON OFF mode The concentrator can detect dry contact openings and closures to report device status or trigger status change alarms ON OFF inputs Digital inputs Type Collector...

Page 37: ...hing threshold disabled 8 mA 1 mA HIGH Switching threshold enabled 15 mA 2 5 mA Power supply voltage Internal 24 V Internal 5 V Pulse counters 20ms 20ms Meters with class A pulse outputs should be use...

Page 38: ...nSunPM Version 2 05 pr liminaire This output has the following specifications Specifications MAX values Voltage 24 V Current 1A The relay output can be controlled using LUA scripts See section3 2 3 1...

Page 39: ...39 USER MANUAL WebdynSunPM Version 2 05 pr liminaire 3 Configuration...

Page 40: ...he equipment pool If the local web interface and the FTP files are modified at the same time the FTP files take precedence Any modifications to files on the FTP server will overwrite any possible loca...

Page 41: ...uration file Description PIN code pin The SIM card PIN code to be entered if it has one APN apn Your mobile operator s APN name required for an IP connection Authentification type authentication Opera...

Page 42: ...which can be PIN code status Description PIN code OK The modem can access the SIM card Either the SIM card PIN code is correct or the SIM card has no PIN code PIN code Required The SIM card expects a...

Page 43: ...dem of 0 to 31 dBm Signal level returned by the modem interpreted in dBm of 113 to 51 IP Address IP address assigned automatically by the mobile operator DNS Address DNS address assigned automatically...

Page 44: ...tion file retrieval on the FTP server They are never a substitute for full FTP or web configuration FTP SFTP As indicated previously this configuration method takes precedence over local configuration...

Page 45: ...DEF directory on the FTP server Please note that the concentrator does not create a configured tree structure Therefore all the configured directories need to be created manually Thus by default the...

Page 46: ...ion uid _scl ini this file contains the configuration parameters for the scripts installed on the concentrator uid _var ini this file contains the concentrator connection scheduling configuration para...

Page 47: ...e 3 1 2 1 2 uid _var ini file The _var ini file contains the scheduling list configured on the concentrator The file name is defined as follows Take the device uid as explained previously and suffix _...

Page 48: ...sday the schedule will be run every Wednesday thursday the schedule will be run every Thursday friday the schedule will be run every Friday saturday the schedule will be run every Saturday sunday the...

Page 49: ...arams 0 1 everyday 00 00 00 1440 1 SCHEDULE2_Params 1 2 everyday 00 00 00 1440 1 SCHEDULE2_Params 2 3 everyday 00 00 00 86400 1 The index number is calculated automatically by the concentrator startin...

Page 50: ...nnected device configuration 3 1 2 1 3 1 Modem configuration Modem configuration is based on the following parameters Parameter Description Default value Type Device type The only possible value here...

Page 51: ...or Always make sure to indicate the delimiter format when saving 3 1 2 1 3 2 Ethernet connection configuration Ethernet interface configuration is based on the following parameters Parameter Descripti...

Page 52: ...mpty Ethernet interframe configuration The interframe time for serial ports is given directly in the configuration for each serial port For Ethernet devices it is more complicated to determine the com...

Page 53: ...guration is based on the following parameters Parameter Description Default value Type Device type The possible values are SERIAL1 to configure the Serial 1 interface SERIAL2 to configure the Serial 2...

Page 54: ...U InterFrame The waiting time between 2 frames exchanges on the serial port This time is expressed in ms See below for a detailed explanation of how this parameter operates 0 Forwarded TCP port Forwar...

Page 55: ...9600 bauds 8 data bits no parity 1 stop bit 2 communication wires modbus protocol and no inter frame time The 2nd serial port is configured at 1200 bauds 4 wires to be used with the SMA Net protocol T...

Page 56: ...SERIAL2 the device is connected to serial port 2 SERIAL3 the device is connected to serial port 3 IP address the device is of the modbus TCP type and is accessible at the indicated IP address IP addr...

Page 57: ...tor fills in this field automatically For TIC devices the field is left empty and will be used in the future Model This field indicates the device model name Note that the concentrator fills in this f...

Page 58: ...tes that the device is of the TIC type o Interface empty As TIC devices use external interfacing equipment supplied by Webdyn this field is ignored o Name tic The name that will be displayed on the lo...

Page 59: ...erter_9301_modbusTCP csv The definition file name that describes the different variables configured for this device detected using SunSpec When editing this file using Excel the following display is s...

Page 60: ...SCRIPT_File 1 Test script 2 lua The index number is calculated automatically by the concentrator starting with 0 If this file is modified manually make sure there are no duplicate index numbers as thi...

Page 61: ...ccepted Files generated automatically or created by the local web interface will be named as follows 3 1 2 2 1 1 TIC The TIC file names are defined as follows File name Description uid _TIC_CBEMM csv...

Page 62: ...o modbusTCP for modbus devices on Ethernet 3 1 2 2 1 4 SMA The SMA file names are defined as follows uid _SMA_ Model csv Model is generated automatically from the SMA Net protocol Model information 3...

Page 63: ...lation of totals issuing of commands to multiple devices etc This name must be unique to allow unambiguous identification and use in the scripts CoefA Contains the multiplier to apply to the variable...

Page 64: ...protocol and are therefore configured as follows 3 1 2 2 2 1 TIC Field Description Info1 This field will be used to indicate the variable description This is the name of the variable to be collected...

Page 65: ...er strings for example The format is the following Register address_Size Thus for example the value 40000 10 configures a variable of which the data is at register 40000 and is 10 bytes long Register...

Page 66: ...n at byte level one by one _WB the words AND the bytes are exchanged The 2 previous modifiers are applied Thus for example the I32_W notation indicates that it is a variable of which bytes 1 and 2 wil...

Page 67: ...ate 2 frames and will not attempt to group the 2 variables together in a single request 3 1 2 2 2 4 SMA Field Description Info1 Channel The channel number for the variable to be collected This informa...

Page 68: ...face To access the concentrator s embedded web interface follow the steps below 1 Launch the web browser The web interface is compatible with the latest browser versions Firefox Chrome and Edge Older...

Page 69: ...rator we recommend changing the default passwords following the first configuration Passwords are modified using the web interface see section 3 2 2 7 Password or using the configuration file see sect...

Page 70: ...following SunSpec The modbus devices in the tables meeting the SunSpec standard specification http www sunspec org can be detected and configured automatically using the Ethernet modbus TCP or serial...

Page 71: ...time By leaving the default value 254 all the devices will be polled and all detectable devices will be detected o Select the interface to use for detection in the Interface field If the device respon...

Page 72: ...56 10 NON SUNSPEC device found at 1 192 93 121 23 502 This means that a modbus device that does not meet SunSpec specifications was found at IP address 192 93 121 23 with modbus address 1 o SunSpec de...

Page 73: ...play result button appears and gives access to the last page The last detection page is used to view all detected devices and eventually to add them to the configuration This screen therefore displays...

Page 74: ...the previous device is not overwritten A new device is created in addition to the pre existing device 3 2 1 1 2 TIC device detection The automatic detection of TIC devices requires the following step...

Page 75: ...the drop down list on the first Protocol field o The other fields will disappear and only TIC 1 will be displayed in the Interface field This field is read only Then click the Start detection button...

Page 76: ...ed It is always possible to interrupt detection by clicking the Abort detection button On completion of the detection the TIC device is imported into the concentrator configuration automatically 3 2 1...

Page 77: ...Net protocol from the drop down list on the first Protocol field o Enter the maximum number of devices to detect in the Max devices field This can speed up the total detection time By leaving the defa...

Page 78: ...A Net scan has begun o As the detection progresses the screen displays the detected devices with their index serial number model and address on the bus Device idx 0 serial 2000388220 model WR21TL09 Ad...

Page 79: ...ht to select the devices to add to the configuration Note that if the detected device is already part of the configuration the checkbox is not checked by default Otherwise the checkbox is checked for...

Page 80: ...ew import the previous device is not overwritten A new device is created in addition to the pre existing device Manual device management Devices can be managed manually on the web site Everything is m...

Page 81: ...to find the corresponding definition file This information cannot be entered directly It is obtained using the internal device definition file database If the required device is not found in the drop...

Page 82: ...ck the Open button Finally click the import button to complete the definition file import A Done message is displayed on the web interface to indicate the operation was successful Once the definition...

Page 83: ...y 502 Slave address the device s modbus address When the device is of the modbus RTU type the following fields are displayed Serial port the serial port to which the modbus slave is connected RTU Slav...

Page 84: ...84 USER MANUAL WebdynSunPM Version 2 05 pr liminaire 3 2 1 2 2 Deleting a device To delete a device first select the device to delete Then click the trash icon under the device description...

Page 85: ...moved from the concentrator databases The modification will be carried over to the configuration files at the next server connection 3 2 1 2 3 Editing a device To edit a device first select the device...

Page 86: ...be modified by importing a new definition file To do that just click the Import Def File button and select the new definition file as indicated in section 3 1 2 1 3 4 Connected device configuration On...

Page 87: ...ebdynSunPM Version 2 05 pr liminaire The first part of the screen is used to configure the 3 digital inputs The fields are Field Description Type Digital input type The authorised values are Dry Loop...

Page 88: ...an alarm is triggered The data read at collection time will be stored in the data file using a single field Contact Indicates the normal status of this input namely its standby state The possible val...

Page 89: ...er to apply to the input so that it complies with the unit described in the unit field This multiplier is a floating point number using a decimal point This factor is there to inform users and is not...

Page 90: ...It then becomes possible to rename and change the definition file by editing the device see section 3 2 1 2 3 Editing a device 3 2 2 Settings All the concentrator settings are grouped together on the...

Page 91: ...ss indicated on the product label see section 2 2 2 Identification Identifier The identifier is used when creating the names of the files uploaded to the server It is important that it be unique to be...

Page 92: ...ort configured in modbus RTU mode SMANET serial port configured for the SMA Net protocol PW1 serial port configured for the PowerOne protocol Mode wires Serial interface mode RS485 2 wires Half Duplex...

Page 93: ...s field the concentrator opens a modbusTCP port on the entered port number When modbusTCP devices connect to this port all sent requests are directly forwarded to the modbusRTU bus and the response is...

Page 94: ...thernet network subnet mask This mask limits the Ethernet network to defined IP addresses and separates the network ranges from each other Gateway gateway Your Ethernet network gateway address The gat...

Page 95: ...ss You can also use the google DNS 8 8 8 8 DNS 2 dns2 DNS 2 server If the DNS1 server fails If your local network is managed by a network administrator contact them before including the WebdynSunPM ga...

Page 96: ...uration file Description PIN code pin The SIM card PIN code to be entered if it has one APN apn Your mobile operator s APN name required for an IP connection Authentification type authentication Opera...

Page 97: ...which can be PIN code status Description PIN code OK The modem can access the SIM card Either the SIM card PIN code is correct or the SIM card has no PIN code PIN code Required The SIM card expects a...

Page 98: ...dem of 0 to 31 dBm Signal level returned by the modem interpreted in dBm of 113 to 51 IP Address IP address assigned automatically by the mobile operator DNS Address DNS address assigned automatically...

Page 99: ...f authentication is required the login and or password are incorrect As long as the problem persists the concentrator will not be able to use the modem to connect to the remote server On the other han...

Page 100: ...ort FTP SFTP server port Login FTP_Login FTP2_Login User name used by the concentrator for the connection to the remote FTP SFTP server Password FTP_Password FTP2_Password Password used by the concent...

Page 101: ...sation Unchecked No certificate synchronisation Data file header option enabled FTP_HeaderOption FTP2_HeaderOption Optional header selection in the data files uploaded to the FTP SFTP server Checked W...

Page 102: ...log is displayed showing all the files exchanged between the concentrator and the remote server Looking at the last line is a quick way to see if the connection was successful or not The ending of an...

Page 103: ...hedule will be run every Sunday First day of each month the schedule will be run on the 1st of every month 15th of each month the schedule will be run on the 15th of every month Last day of each month...

Page 104: ...rvals you can enter a value of more than 1440 in Count Example 1 For a regular file upload every hour the schedule should be configured as follows Example 2 For a regular file upload every Sunday at m...

Page 105: ...which are then uploaded to the remote server by the concentrator For example if you select the GMT 01 00 Europe Brussels Copenhagen Madrid Paris time zone the concentrator will indicate The date and...

Page 106: ...lo GMT 02 00 Brazil GMT 01 00 Azores UTC GMT 01 00 Europe Brussels Copenhagen Madrid Paris GMT 01 00 Algiers GMT 02 00 Athens Bucharest Istanbul GMT 02 00 Cairo GMT 03 00 Moscow St Petersburg Volgogra...

Page 107: ...T 11 00 Magadan Solomon Islands GMT 13 00 Auckland Wellington The time differences for countries are not taken into account by the concentrator NTP The NTP settings are Web interface Parameter in the...

Page 108: ...rver This server does not guarantee the exactness of the time synchronisation nor its robustness The use of a specific NTP server is strongly recommended Contact an NTP server portal or supplier After...

Page 109: ...ible to re display the last connection log by clicking the Magnifier button The concentrator time can be synchronised with the PC time by clicking the Set time from PC button The time zone configured...

Page 110: ...the default passwords following the first configuration The password can also be changed using the WEB_Password variable in the config file uid _config ini If you lose the password and no servers are...

Page 111: ...WebdynSunPM LUA User Guide pdf Script configuration and management are accessed from the local web site page This page can be used to import new scripts enable them disable them or even delete them o...

Page 112: ...cript will appear in the script management window Note that the scripts are imported stopped this means they are not started automatically The information displayed on the web page comes from the scri...

Page 113: ...of what can be done Disabling a script meets stopping it from running Note that scripts are run automatically when the WebdynSunPM concentrator starts up even if they were disabled before the start u...

Page 114: ...utton displays the following page The page is closed by pressing the cross at the top right indicated above in the circle 3 2 3 1 4 Viewing the script It is possible to display the source code for the...

Page 115: ...g a script Pressing the script export button launches an immediate local script load by the browser When the user clicks this button the script is loaded directly into the browser downloads directory...

Page 116: ...update the the concentrator 1 Retrieve the firmware from the web site see section 5 Update https www webdyn com support webdynsunpm 2 Unzip the retrieved file 3 Click the Select your firmware file fie...

Page 117: ...the concentrator s Upgrade page 11 Check that the new version is shown in the Firmware version field The concentrator has been updated Do not disconnect the concentrator and avoid operations on it du...

Page 118: ...ns the browser page needs to be refreshed using the F5 function for example to be able to log back in Text message command Commands can be sent to the WebdynSunPM concentrator modem by text message Be...

Page 119: ...command The ftp command is used to configure the Server 1 FTP server Syntax ftp server login password port interface Parameters server the name of the FTP server to connect to This parameter can be a...

Page 120: ...e the concentrator identifier uid firmware version the version of firmware currently loaded on the concentrator 2 6 eth0 ip ipaddr mask mask gw gateway dns dns ipaddr IP address configured on the eth...

Page 121: ...status status type type mode mode addr ipaddr port port last server configured server 1 name status indicates whether server 1 is enabled or not The possible values are o enabled server 1 is enabled o...

Page 122: ...er 2 is of the MQTTS type mode the server 2 running mode The possible values are o strategy_wsun1_compliant_backup the server is an FTP type server and is configured as a backup server o strategy_wsun...

Page 123: ...en detected on the interface Responses When the detection completes successfully the following message is returned SunSpec detection finished in counter seconds devices detected and added The detectio...

Page 124: ...124 USER MANUAL WebdynSunPM Version 2 05 pr liminaire factory Parameters none...

Page 125: ...125 USER MANUAL WebdynSunPM Version 2 05 pr liminaire 4 Operation...

Page 126: ...s must be uploaded to the server in an INBOX directory associated with the concentrator Monitor the concentrator and assist in diagnosis The concentrator can upload log files for diagnosis purposes If...

Page 127: ...ry the FTP server must have the following directories Name Rights Description CONFIG Read Write Contains the configuration files The concentrator configuration uploaded by the concentrator is in the f...

Page 128: ...r interface the interface name from a defined list see section 3 1 2 2 2 Definition file content comment free user field version update version number The data alarm and log files are compressed to th...

Page 129: ...mmand file Alarm file Delimited data file in the form of semi colon delimited values easy to use with Excel type spreadsheet software lua Script file Lua language script pem Certificate file PEM forma...

Page 130: ...the new configuration has been applied the result is indicated in the concentrator s log file If there is an error in the configuration file such as an incorrect value the concentrator will not take...

Page 131: ...it has the following format uid _ interface _ comment csv Where uid Concentrator identifier interface the interface name from a defined list see section 3 1 2 2 2 Definition file content comment free...

Page 132: ...ator can store up to 50Mb of uncompressed data per defined device The WebdynSunPM permanently collects the device and interface data and saves it The reported values are always raw and must be connect...

Page 133: ...rmatting is identical regardless of the device or interface The reported values are raw and must be linked to the configuration on the device or the interface in its definition file The IS must interp...

Page 134: ...g data to the server and thereby optimise the connection it is recommended to only enable the variables that need to be reported TIC The webdynSunPM permanently collects the data from the TIC flow and...

Page 135: ...Input Output IO Example of an IO data file with an acquisition frequency of every 10 seconds Input output configuration Input Output Action code Display 1 4 Instant value 2 0 None 3 4 Instant value 4...

Page 136: ...avg 21 02 05 09 50 00 16 32 26 00 52 58 51 00 21 02 05 10 00 00 4 6 05 50 102 105 103 00 4 1 4 ALARM alarms Alarms are uploaded in the form of CSV format files compressed to Gzip gz format They are up...

Page 137: ...5 Servers info_X Information on alarm X The IO and MODBUS type alarm file format is the following Colour code Blue Device specific information or data Where datetime_Y alarm timestamp at trigger poin...

Page 138: ...7 00 49 MODBUS MODBUS_DELTA_M88H COM1 20 Sunspec csv OndA 48 3 000000 4 1 5 CMD commands Future upgrade 4 1 6 SCRIPTS The SCRIPT directory on the FTP server is used to supply or retrieve Lua scripts t...

Page 139: ...logs uid _SYSTEM_ date log gz 4 1 8 1 Connection logs Every time the concentrator connects to a server either by modem or Ethernet all operations are saved for future viewing When the connection is f...

Page 140: ...king Test script 2 lua 2021 02 11 14 25 21 No change 2021 02 11 14 25 21 Configuration file summary 2021 02 11 14 25 21 WPM00BDE4_SunSpec_inverter_SMA_Solar_Inverter_9301_modbusTCP csv Action Get remo...

Page 141: ...g remote changes Modifications were also detected on the devices and the _daq csv file is sent to the FTP server 2021 02 11 14 25 21 Local changes sent WPM00BDE4_daq csv The processing completes with...

Page 142: ...n The log file can be viewed in 2 ways Either directly on the local web site on the script page by clicking the view log icon see section 3 2 3 1 Scripts Or on the FTP server in the log files The logs...

Page 143: ...0087 126 192 93 121 23 502 21 02 11 17 27 51 Found table 101 50 at 40187 126 192 93 121 23 502 21 02 11 17 27 52 Found table 120 26 at 40239 126 192 93 121 23 502 21 02 11 17 27 53 Found table 121 30...

Page 144: ...on must be enabled on the server configuration page The system log files are also transferred automatically when a connection is forced from the server configuration page by clicking the Connect butto...

Page 145: ...145 USER MANUAL WebdynSunPM Version 2 05 pr liminaire 5 Update...

Page 146: ...ning the updates in the BIN directory on the remote server 2 Edit the uid _config_ ini file uid Concentrator identifier which is in the CONFIG directory on the FTP server Put the file name that has ju...

Page 147: ...147 USER MANUAL WebdynSunPM Version 2 05 pr liminaire...

Page 148: ...148 USER MANUAL WebdynSunPM Version 2 05 pr liminaire 6 Tools diagnostics...

Page 149: ...trator function in order to better isolate problems If necessary the concentrator can also be rebooted remotely using the reboot text message command see section 3 3 4 reboot command The product can a...

Page 150: ...150 USER MANUAL WebdynSunPM Version 2 05 pr liminaire 7 Support...

Page 151: ...78100 Saint Germain en Laye Phone 33 1 39 04 29 40 Email support webdyn com https www webdyn com Please have the following elements to hand Product type Product serial number Product hardware and sof...

Page 152: ...152 USER MANUAL WebdynSunPM Version 2 05 pr liminaire 8 FAQ...

Page 153: ...i etc and enter the WebdynSunPM concentrator IP address in the address bar An authentication page is displayed The default accesses are Login Password userhigh high Click Login How do you configure th...

Page 154: ...on the configuration must be compatible with the concentrator s local network topology so that it can access the servers This configuration is done from the Networks configuration page see section 3 2...

Page 155: ...entration configuration see section 3 3 3 ftp FTP configuration command ftp server login password port interface o Connect to launch the connection to the FTP server and load the configuration see sec...

Page 156: ...number see section 3 3 7 factory reset command The factory reset restores the original configuration The data is not kept Can the gateway send commands to connected devices It is possible to send comm...

Page 157: ...ion 1 4 Supported devices Modbus device compatibility Can I connect different Modbus devices to the same serial port Yes different Modbus devices can be connected to the same serial port Device compat...

Page 158: ...ti tariff blue meter CBEMM Single phased electronic multi tariff blue meter CBEMM ICC evolution Three phased electronic multi tariff blue meter CBETM Electronic yellow meter CJE Interface Client le Em...

Page 159: ...159 USER MANUAL WebdynSunPM Version 2 05 pr liminaire 9 APPENDICES...

Page 160: ...ate configuration for how to use updates 3 1 2 1 Concentrator_Identifier Gateway identifier uid If this field is left empty the default identifier is used WPMABCDEF where ABCDEF are the last character...

Page 161: ...2 Concentrator operation CONFIG FTP_DirData FTP 1 server directory to which the concentrator uploads the data files collected during operation Note that the directory MUST exist The concentrator will...

Page 162: ...on to the FTP 1 server is kept alive This value is expressed in seconds A value of 0 indicates that the connection is ended as soon as processing completes 0 FTP_EuroDateFormat Indicates the format us...

Page 163: ...d Note that the directory MUST exist The concentrator will not create it when uploading files ALARM FTP2_DirBin FTP 2 server directory in which the concentrator will get the update files when requeste...

Page 164: ...ate it when uploading files See the section on definition file configuration for the operating principle see section 3 1 2 2 Connected device definition DEF FTP2_DirLog FTP 2 server directory to which...

Page 165: ...connect to server FTP 2 FTP2_Port The network port to use to connect to the FTP 2 server 21 FTP2_SynchroniseCertificates Future upgrade 0 FTP2_TwoStepsSendingDisabled Used for file transfers in 2 ste...

Page 166: ...The possible values are ethernet uses the ethernet connection modem uses the 3G interface with the embedded SIM card This parameter cannot be empty ethernet SERVER_Type The type of server to which the...

Page 167: ...rver type The possible values are ftp FTP server sftp SFTP server mqtt MQTT server mqtts secure MQTT server mqtts_aws MQTTS server on AWS IoT mqtts_gcloud MQTTS server on Google Cloud IoT This paramet...

Page 168: ...03 00 Antarctica GMT 03 00 Sao Paulo GMT 02 00 Brazil GMT 01 00 Azores UTC GMT 01 00 Europe Brussels Copenhagen Madrid Paris GMT 01 00 Algiers GMT 02 00 Athens Bucharest Istanbul GMT 02 00 Cairo GMT...

Reviews: