63
USER MANUAL
–
WebdynSunPM
Version 2.05
préliminaire
The Category, Manufacturer and Model are used to find the device’s associated definition file
from the web pages.
Following this first row, all the following rows will contain the device variable definitions.
Each row fully describes a variable.
Each row will have the following format:
Index ; Info1 ; Info2 ; Info3 ; Info4 ; Name ; Tag ; CoefA ; CoefB ; Unit ;
Action
The field meanings are the following:
Field
Description
Index
Contains the unique variable identifier in the file. It is free form for the client as long as
it remains unique. This field is used to identify the variables in the data file, the logs or
the command files.
Info1
This field contains information specific to the protocol used on the device. Refer to the
specific protocol documentation below.
Info2
This field contains information specific to the protocol used on the device. Refer to the
specific protocol documentation below.
Info3
This field contains information specific to the protocol used on the device. Refer to the
specific protocol documentation below.
Info4
This field contains information specific to the protocol used on the device. Refer to the
specific protocol documentation below.
Name
Contains the variable name, which is free form as long as it is unique.
Tag
Contains an identification making it possible to use the variable in scripts. (Calculation
of totals, issuing of commands to multiple devices, etc.). This name must be unique to
allow unambiguous identification and use in the scripts.
CoefA
Contains the multiplier to apply to the variable so that it complies with the unit
described in the “unit” field. This multiplier is a floating point number using a decimal
point “. “
CoefB
Contains the offset to apply to the variable so that it complies with the unit described
in the “unit” field. This offset is a floating point number using a decimal point “. “
Factors A and B will contain the appropriate value by default if it is known, otherwise A
is 1 and B is 0. If the values are missing, these values will be considered to be 1 and 0.
The factors are there to inform users and are not applied on the data sent in the data
files. This operation is the responsibility of operators who, if they want to convert the
sent raw data, must carry out the “
Ax+B
” op
eration on data x, in particular to obtain a
value in the unit indicated in the “unit” field
These factors are applied to the values used by the scripts and by the return mechanism
to a display to obtain a value indicated in the “
unit
” field.
Unit
Contains the required unit. As for the factors, this field contains the appropriate
information if it is known, otherwise the field is empty. This field is information for the
user and it is up to the client to make sure it matches the entered A and B factors.
Action
Contains the code describing the processing to be carried out by the product on this
variable when the files for the IS are created.
The possible actions are:
Summary of Contents for WebdynSunPM
Page 1: ...WebdynSunPM Supervision gateway for photovoltaic installations USER MANUAL...
Page 9: ...9 USER MANUAL WebdynSunPM Version 2 05 pr liminaire 1 Presentation...
Page 18: ...18 USER MANUAL WebdynSunPM Version 2 05 pr liminaire 2 Installation and Maintenance...
Page 39: ...39 USER MANUAL WebdynSunPM Version 2 05 pr liminaire 3 Configuration...
Page 124: ...124 USER MANUAL WebdynSunPM Version 2 05 pr liminaire factory Parameters none...
Page 125: ...125 USER MANUAL WebdynSunPM Version 2 05 pr liminaire 4 Operation...
Page 145: ...145 USER MANUAL WebdynSunPM Version 2 05 pr liminaire 5 Update...
Page 147: ...147 USER MANUAL WebdynSunPM Version 2 05 pr liminaire...
Page 148: ...148 USER MANUAL WebdynSunPM Version 2 05 pr liminaire 6 Tools diagnostics...
Page 150: ...150 USER MANUAL WebdynSunPM Version 2 05 pr liminaire 7 Support...
Page 152: ...152 USER MANUAL WebdynSunPM Version 2 05 pr liminaire 8 FAQ...
Page 159: ...159 USER MANUAL WebdynSunPM Version 2 05 pr liminaire 9 APPENDICES...