background image

4

PULL ACROSS - PUMP REMOVAL

Figure E - Pull Across pump removal (top view)

E1

    E1. Disconnect power to pump. Using the included 25 ft. rope, safely 

pull pump to edge of pool, disconnect discharge hose and remove.

 

 

  Never use power cord to position, carry or 

                                               retrieve the pump.

 will be pumped.

 Do 

NOT handle pump with wet       

  hands or when standing in water 

or on a 

damp surface when the unit is operating or fails to operate. 

ALWAYS 

disconnect pump power cord from power source before 

handling. Do NOT bury cord. Visually locate cord to prevent 

damage 

caused by lawn mowers, hedge trimmers and other equipment. Failure to do so 

WILL result in fatal electrical shock.

   

 

    

Do NOT alter the pump to override the automatic

  water detector. The shaft seal depends on water for 

lubrication. Overriding this pump feature CAN cause the pump to run dry and MAY 

damage the shaft seal and cause pump failure.

5.   The water level must be at least 2-1/8 inches for the 

pump to cycle, prime, and operate. Water levels less 
than 2-1/8 inches will not allow the impeller to contact 
water therefore no water will be pumped.

6.   Plug the pump into a properly grounded 120 volt GFCI 

protected outlet. The pump will start automatically when 
the water reaches a depth of 2-1/8 inches. A priming 
delay of 2 seconds is programmed into the control to 
allow time for air to escape from the pumping chamber. 

  Use caution when positioning the pump not to     

 

damage the power cord by dragging across the edge of the 

pool.  Also take into consideration the placement of the discharge hose and power cord 

after installation.  Make sure no sharp edge can damage the power cord or discharge 

hose causing unsafe conditions.

7.   The pump will stop automatically once water has been 

removed to a depth of approximately 3/4 of an inch. The 
pump will NOT restart until the water depth rises to 2-1/8 
inches or greater. 

8.   The pump will NOT allow itself to run dry. Once the pump 

detects that water is no longer being removed, it will shut 
down automatically. The pump must remain upright at all 
times in order for the water detection to function. Do NOT 
allow the pump to operate on its side or inverted The shaft 
seal depends on water for lubrication, allowing the pump 
to remain in any other orientation than upright could cause 
shaft seal failure or pump failure.

 

Pump starts automatically.            

  Always disconnect electric supply before attempting 

to install, service, relocate, or perform any maintenance.

Minimal service is required for this pump. The motor 

housing of the pump is completely sealed and requires 

no service. If pump should fail to operate, perform the 

following troubleshooting guidelines:

PRIMING HOLE 

BASE SCREWS (4)

INLET SCREEN/ BASE

IMPELLER 

Figure 1 - Priming Hole Location

WHEN REATTACHING THE BASE (INLET SCREEN), BE SURE THAT 

THE SIX (6) “PLUGGED” HOLES ARE ORIENTED BELOW THE SWITCH 

5.   Periodic cleaning is required to maintain performance of 

the pump. Follow the cleaning steps listed below: 
a.  Disconnect pump from power source.
b.  Remove the strainer.
c.  Remove the four (4) base screws (Figure 1).
d.  Remove the base and impeller plate.
e.  Remove the debris and make sure the impeller turns 

freely.

f.  Reinstall impeller plate, base, screws, and strainer.

1.   Verify pumping height does NOT exceed 13 feet (See 

Figure A). If pumping height is greater than 13 feet, this 
pumps automatic feature will not operate correctly.

2.   Verify water depth is 2-1/8 inches or greater. 

3.   To verify pump is operating correctly.

a.  Disconnect pump from power source.
b.  Connect hose adapter/check valve and discharge 

hose to pump.

c.  Immerse pump in a bucket or tub of water at least 

2-1/8 inches in depth.

d.  Place the other end of the discharge hose outside 

the bucket, so the water will pump out.

e.  Plug power cord into a grounded 120 volt GFCI 

power outlet. The pump should start after 2 seconds 

of detecting water. Once the pump removes the 

water to a depth of 3/4 inch, the pump will stop 

automatically. 

f.  If pump appears to turn on but not move water 

unplug power cord and proceed to step 4.  if pump 

does NOT operate, unplug power cord and proceed 

to 

maintenance step 5.

a.  Connect hose to another water source such as 

a faucet. If water flows through hose, return to 

step 3a. If water is restricted, verify discharge 

MAINTENANCE

Electrocution Hazard! 

PLUGGED HOLES

Operating Instructions and Parts Manual

www.waynepumps.com

4.  To verify discharge hose is free from a lockage:

Summary of Contents for WAPC250

Page 1: ...VE STEP 3 ATTACH STRAINER STEP 4 CONNECT GARDEN HOSE STEP 5 SECURE ROPE TO STRAINER STEP 6 POSITION ON POOL COVER STEP 7 PLUG INTO GFCI OUTLET FOR FURTHER PLACEMENT TECHNIQUES AND DETAILED INSTALLATIO...

Page 2: ...d the female end of the garden hose to the male end of the garden hose adapter check valve DESCRIPTION This portable Auto On Off Pool Cover pump is designed for automatic removal of water from a pool...

Page 3: ...help prevent clogging PULL ACROSS PUMP INSTALLATION To aid in pump placement on pool cover secure provided 25 ft rope to the pull to shore loop Figure B Figure A In ground pool installation cut away...

Page 4: ...the pump to operate on its side or inverted The shaft seal depends on water for lubrication allowing the pump to remain in any other orientation than upright could cause shaft seal failure or pump fai...

Page 5: ...bly caused by debris buildup or from a frozen impeller situation caused by ice formation When the pump is activated and a locked impeller condition is detected the unit will automatically shutdown to...

Page 6: ...specific legal rights and you may also have other legal rights which vary from state to state In no event whether as a result of breach of contract warranty tort in clud ing negligence or otherwise s...

Page 7: ...Notes 7 WAPC250 www waynepumps com...

Page 8: ...OSITIONNEMENT SUR LA COUVERTURE DE LA PISCINE TAPE 7 BRANCHEMENT DANS UNE PRISE DISJONCTEUR DE FUITE LA TERRE LE WAPC250G POSS DE UNE PRISE PROT G E PAR UN DISJONCTEUR DE FUITE DE TERRE POUR LES AUTRE...

Page 9: ...a rallonge de la pompe tomber dans la piscine ou entrer en contact avec l eau La connexion de la pompe rallonge doit tre gard e au sec et l abri de l humidit NE PAS manipuler le connecteur pr s de l e...

Page 10: ...de traction vers le bord Figure B Figure A Installation pour une piscine enterr e vue en coupe A2 A3 TUYAU DE D CHARGE VITER TOUT PINCEMENT OU ENDOMMAGEMENT DU CORDON D ALIMENTATION ET DU TUYAU SUR L...

Page 11: ...d eau fonctionne NE PAS laisser la pompe fonctionner sur le c t ou l envers Le joint de l arbre compte sur l eau pour sa lubrification Ainsi si la pompe n est pas maintenue droite cela pourrait La pom...

Page 12: ...mps afin d essayer de lib rer l impulseur apr s quoi l appareil s arr tera et restera hors tension pendant 12 heures v rifiant deux fois par jour si l impulseur est lib r Une fois que la pompe sera no...

Page 13: ...ts l gaux qui varient d une juridiction l autre En aucun cas soit par suite d une rupture de contrat de garantie acte dommageable y compris la n gligence ou autre ni WAYNE Pumps ni ses fournisseurs ne...

Page 14: ...Remarques 14 FR www waynepumps com Manuel de pi ces et mode d emploi...

Page 15: ...DE JARD N PASO 5 SUJETE LA CUERDA AL FILTRO PASO 6 COLOQUE LA BOMBA SOBRE LA CUBIERTA DE PISCINA PASO 7 ENCHUFE EN UN TOMACORRIENTE GFCI WAPC250G TIENE ENCHUFE PROTEGIDO CON GFCI PARA OBTENER M S T C...

Page 16: ...NAR lesiones graves o la muerte Esta unidad NO est dise ada para usarse como una bomba de sumidero o en aplicaciones de sumidero Esta unidad NO est dise ada para usarse en tanques s pticos ni en s tan...

Page 17: ...25 pies que se suministra al pestillo de sujeci n Figura B Figura A Instalaci n en piscina enterrada vista seccionada A2 A3 MANGUERA DE DESCARGA EVITE APRETAR O DA AR EL CABLE DE CORRIENTE Y LA MANGUE...

Page 18: ...que la detecci n de agua funcione EVITE que la bomba funcione de costado o en posici n invertida El sello del eje utiliza agua para su lubricaci n Si la bomba permanece en cualquier otra orientaci n q...

Page 19: ...tivada y se detecta una condici n de bloqueo del impulsor la unidad se apaga autom ticamente para evitar que el motor se sobrecaliente La bomba continuar este ciclo de encendido apagado durante un tie...

Page 20: ...os derechos legales que pueden variar de un estado a otro Bajo ning n concepto ya sea por incumplimiento del contrato de garant a agravio incluida la negligencia o de otro modo WAYNE Pumps o sus prove...

Reviews: