background image

340107-001  9/10

 REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or fi le it for safekeeping.

 Description

Shallow well jet pumps are single stage 
domestic water pumps designed for 
pumping portable water in applications 
where the water is located less than 
25 feet vertically from the pump.  A 
pressure switch is a standard feature.  
The shallow well pump can be mounted 
to either a pre-charged, conventional 
type or free standing pressure tank.

Unpacking

After unpacking the jet pump, carefully 
inspect for any damage that may have 
occurred during transit.  Check for loose, 
missing or damaged parts.

Safety Guidelines

This manual contains information that is 
very important to know and understand. 
This information is provided for SAFETY 
and to PREVENT EQUIPMENT PROBLEMS. 
To help recognize this information, 
observe the following symbols. 

 

Danger indicates an 

 imminently hazardous 

situation which, if not avoided, will result 
in death or serious injury.

 

Warning indicates a 

 potentially hazardous 

situation which, if not avoided, could 
result in death or serious injury.

 

Caution indicates a 

 potentially hazardous 

situation which, if not avoided, may 
result in minor or moderate injury.

 Notice 

indicates 

 important 

information, that if not followed, may 
cause damage to equipment.

General Safety 
Information

 CALIFORNIA PROPOSITION 65

 

This product or its

  power cord may contain 

chemicals known to the State of California 
to cause cancer and birth defects or other 
reproductive harm. Wash hands after handling.  

GENERAL SAFETY

1.  Read the instruction manual included 

with the product carefully.  Be 
thoroughly familiar with the controls 
and the proper use of the equipment.

2.  Know the pump application, 

limitations and potential hazards.

 

Always install a 

  pressure relief valve 

to match the system pressure rating and 
the maximum fl ow rate.
 

Do not use to pump 

  fl ammable or 

explosive fl uids such as gasoline, 
fuel oil, kerosene, etc. Do not use in 
explosive atmospheres. Pump should 
only be used with liquids compatible 
with pump component materials. Failure 
to follow this warning can result in 
personal injury and/or property damage. 
 Disconnect 

power 

  and release all 

pressure from the system before 
attempting to install, service, relocate 
or perform any maintenance. Lock the 
power disconnect in the open position. 
Tag the power disconnect to prevent 
unexpected application of power.
 

 Install a screen

  around the inlet pipe 

to prevent entrapment of swimmers.

3.  Drain all liquids from the system 

before servicing.

4.  Secure the discharge line before 

starting the pump.  An unsecured 
discharge line will whip and possibly 
cause personal injury and/or property 
damage.

5.  Check hoses for weak or worn 

condition before each use.  Make 
certain all connections are secure.

6.  Periodically inspect pump and system 

components.  Perform routine 
maintenance as required (See 
Maintenance).

7. Personal Safety:  

a. Wear safety glasses at all times 

when working with pumps.

b. Keep work area clean, uncluttered 

and properly lighted - replace all 
unused tools and equipment.

c. Keep visitors at a safe distance 

from work area.

d. Make the workshop childproof 

use padlocks, master switches and 
remove starter keys.

8.  Do not pump chemicals or corrosive 

liquids.  Pumping these liquids 
shortens the life of the pumps seals 
and moving parts and will void the 
warranty.

9.  When installing pump, cover the 

well to prevent foreign matter from 
falling into well and contaminating 

the water and damaging internal 
mechanical pumping components.

10. Always test the water from the well 

for purity before use.  Check with local 
health department for test procedure.

11. Complete pump and piping system 

MUST be protected against below 
freezing temperature.  Freezing 
temperatures could cause severe 
damage and void the warranty.

12. Do not run the pump dry or damage 

will occur and will void warranty.

 

Risk of electrical

  shock.  This pump is 

designed for indoor installation only.

 

All wiring should be

  performed by a 

licensed or certifi ed electrician.

13. For maximum safety, the unit should 

be connected to a grounded circuit 
equipped with a ground fault 
interrupter device.

14. Before installing the pump, have the 

electrical outlet checked by a licensed 
or certified electrician to make sure 
the outlet is properly grounded.

15. Make sure the line voltage and 

frequency of electrical current supply 
agrees with the motor wiring.

16. Do not attempt repairs to the electric 

motor.  All repairs to the motor 
must be completed at a licensed or 
certified electrical motor repair shop.

 

Do not touch an

  operating motor.  

Modern motors are designed to operate 
at high temperatures.

17. Avoid kinking electrical cord and 

protect from sharp objects, hot 
surfaces, oil and chemicals.  Replace 
or repair damaged or worn cords 
immediately.

 Disconnect 

power

  and release all 

pressure from the system before 
attempting to install, service, relocate 
or perform any maintenance.  Lock the 
power disconnect in the open position.  
Tag the power disconnect to prevent 
unexpected application of power.

18. Keep fingers and foreign objects 

away from ventilation and other 
openings.  Do not insert any objects 
into the motor.

 

Risk of electric shock!

  Never connect the 

green (or green and yellow wire) to a 
live terminal! 

© 2010 WAYNE Water Pumps

For parts, product & service information

visit 

www.waynepumps.com

Operating Instructions and Parts Manual

 

Shallow well model systems

Jet Pump Water System

 Please read and save these instructions. Read carefully before attempting to 
assemble, install, operate or maintain the product described. Protect yourself 
and others by observing all safety information. Failure to comply with 
instructions could result in personal injury and/or property damage! Retain 
instructions for future reference.

Summary of Contents for Shallow well model

Page 1: ...ure 6 Periodically inspect pump and system components Perform routine maintenance as required See Maintenance 7 Personal Safety a Wear safety glasses at all times when working with pumps b Keep work a...

Page 2: ...r This barrier prevents the air from being absorbed into the water and allows the water to be acted on by compressed air at initially higher than atmospheric pressures precharged More usable water is...

Page 3: ...oints or couplings will allow air to leak into the pipe and cause abnormal pump operation Make sure to use pipe joint compound on all male pipe threads DUG WELL CISTERN LAKE AND SPRING INSTALLATION FI...

Page 4: ...ny maintenance Operation PRIMING THE SHALLOW WELL PUMP To prevent damage to the pump do not start motor until pump has been filled with water 1 Remove prime plug Figure 4 or 5 2 Fill pump and piping c...

Page 5: ...from impeller hub and seal plate INSTALLING NEW SHAFT SEAL Before handling shaft seal parts wipe hands clean Dirt or grease can damage the seal 1 Wet the inside of the seal cavity on seal plate and th...

Page 6: ...6 Operating Instructions and Parts Manual Shallow Well Model Systems www waynepumps com Notes...

Page 7: ...7 Operating Instructions and Parts Manual Shallow Well Model Systems Notes www waynepumps com...

Page 8: ...8 Operating Instructions and Parts Manual Shallow Well Model Systems www waynepumps com Notes...

Page 9: ...well 7 Air volume control diaphragm ruptured 8 Foot valve may be clogged or stuck closed 9 Pump not fully primed 10 Control valve completely closed deep well 11 Water level below maximum lift specific...

Page 10: ...assembly 56393 56393 56393 1 6 Impeller 23285 021 23285 022 23285 022 1 7 Diffuser 17148 021 17148 021 17148 021 1 8 Screw 67007 001 67007 001 67007 001 2 9 O ring 15557 15557 15557 1 10 Venturi 1715...

Page 11: ...concrete to prevent cave in D DRIVEN WELL Pipe with a pointed screen is driven into the ground below the water table The depth is usually less than 50 feet Available diameters are 1 through 2 E DRILL...

Page 12: ...AGES OR EXPENSES WHATSOEVER IS EXCLUDED Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitations of incidental or consequential damages...

Page 13: ...d essayer de monter de d placer ou de proc der au service ou l entretien Verouiller le sectionneur de puissance dans la position ouverte tiquetter le sectionneur de puissance afin d viter l alimentat...

Page 14: ...de d charge basse tension tr s lev e ou basse installation de fils incorrecte branchements de moteur incorrects ou moteur pompe d fectueux Pr Installation SOURCES D EAU Les sources d eau possibles so...

Page 15: ...mpe pour puits de surface si la pompe est situ e moins de 7 62 m verticalement du niveau d eau Les pompes pour puits de surface ont un seul tuyau entre la pompe et la source d eau Figure 3 PUITS FOR F...

Page 16: ...La tension de la source d alimentation doit correspondre avec la tension de la pompe Toutes les pompes de puits de surface sauf le mod le SWS50BOOST ont des moteurs tension double pr r gl s en usine 1...

Page 17: ...le plus bas du syst me pour dissiper toute l eau pressuris e dans le syst me 3 Amorcer la pompe Amor age De Pompes Pour Puits De Surface 4 Brancher nouveau l alimentation la pompe REMARQUE Lors du rem...

Page 18: ...assure le vidange et l amor age correct 3 Positionner la pi ce du joint d arbre rotative sur la turbine et appuyer soigneusement afin de ne pas appuyer sur la surface polie du joint 4 Positionner la t...

Page 19: ...effonde D PUITS ENFONC Un tuyau avec un tamis pointu est enfonc dans la terre sous le niveau hydrostatique La profondeur est g n ralement moins de 15 m Les diam tres disponibles sont 2 5 cm 5 1 cm E P...

Page 20: ...anneau carr 17150 001 1 5 Assemblage de bo te d tanch it 56393 1 6 Rotor 23285 002 1 7 Diffuseur 17148 001 1 8 Vis 67007 001 9 Joint torique 15557 1 10 Venturi 17151 002 1 11 Buse 15672 1 12 Bouchon...

Page 21: ...aisser la circulation aller retour de la pompe b Purger l air enferm dans la pompe normalement cause d une vanne ferm e dans la plomberie de d charge 2 Filtre en ligne r duit la circulation 2 V rifier...

Page 22: ...dur e pour les garanties implicites ni l exclusion ni la limite des dommages fortuits ou indirects Les limites pr c dentes peuvent donc ne pas s appliquer Cette garantie limit e donne l acheteur des...

Page 23: ...s materiales 5 Antes de cada uso inspeccione las mangueras para cerciorarse de que no est n d biles ni gastadas Aseg rese de que todas las conexiones est n seguras 6 Inspeccione peri dicamente la bomb...

Page 24: ...cisterna Esta agua habitualmente no es adecuada para consumo humano pero podr a usarse para lavar irrigar u otros usos dom sticos AGUAS SUBTERR NEAS El agua que se encuentra en los diversos estratos p...

Page 25: ...vula de aspiraci n debe estar por lo menos a 45 cm 18 pulg del fondo del pozo de no ser as podr a aspirar arena o sedimento dentro del sistema 4 Despu s que se haya alcanzado la profundidad adecuada i...

Page 26: ...i n sobre superficie excepto la SWS50BOOST tienen motores de doble voltaje preconfigurados en la f brica a 115 voltios Para conectarlas a circuitos de 230 voltios simplemente gire la perilla al voltaj...

Page 27: ...ebe haber agua en la cubierta en espiral de la bomba voluta cuando este funcionando para evitar danos internos en las piezas de sellado Vea las secciones sobre cebado de pozos poco profundos o de pozo...

Page 28: ...alineadas con las leng etas del armaz n del motor Figura 11 Esta ubicaci n se debe hacer para asegurar un drenaje y cebado adecuados 3 Sit e la pieza rotatoria del sello del eje en el impulsor y pres...

Page 29: ...el flujo hacia y desde la bomba b Deje salir el aire atrapado en la bomba normalmente debido a una v lvula cerrada en la tuber a de salida 2 El filtro en l nea est restringiendo el flujo 2 Verifique...

Page 30: ...A No de Ref Descripci n No Repuestos Cte 1 Motor 32059 001 1 2 Tornillo 16636 002 3 Plato de cierre 17145 001 1 4 Junta cuadrada de goma del anillo 17150 001 1 5 Ensamblaje de sellado del eje 56393 1...

Page 31: ...POZO ACCIONADO Se acciona una tuber a con una pantalla con punta en la tierra por debajo de la capa fre tica La profundidad por lo general es menor a 15 25 m 50 pies Los di metros comunes fluct an ent...

Page 32: ...XCLUIDOS Algunos estados no permiten que se establezcan l mites en la duraci n de las garant as implicitas o no permiten que se excluyan ni se establezcan l mites en los da os por incidentes o consecu...