Page 55 of 59
SETUP COMMAND
You may program the
WaveWare v
8
Paging Encoder
to monitor for interference using the
Carrier Detect
mode. If the
Carrier Detect
mode is turned
“ON”
, the paging encoder will hold paging messages in queue until an offending carrier
signal is no longer detected at the transmission frequency of the paging encoder. The settings programmed by the
Setup command will be remembered by the paging encoder even if power is removed from the paging encoder.
The Setup Command
is formatted as follows:
<SOH>S,X,V<EOT>
Where the S indicates Setup Mode,
X
is the command type, and
V
is the value. The comma delimiters are
optional.
X
A single numeric value used to indicate the command type. The numeric character is followed by
a comma.
Valid values
(X)
are:
1 =
Carrier Detect Mode
V
A single numeric value used to indicate the value of the command setting to be saved. The
numeric character is followed by an
EOT
character.
Valid values
(V)
are:
0 =
Off
1 =
On
Example 1:
<SOH>S,1,0<EOT>
will set the Carrier Detect function to the
“Off”
status.
Example 2:
<SOH>S11<EOT>
will set the Carrier Detect function to the
“On”
status.
STATUS COMMAND
You may request the paging encoder to respond with its current programmed settings using the Status command.
The Status command is formatted as follows:
<SOH>S?<EOT>
Where the
S?
requests the paging encoder to respond with the status of its current programmed settings. The
Status Command can be used in supervisory controlled applications to ensure the encoder is still functioning,
without causing unwanted paging transmissions.
This Completes “Status Commands”
This Completes the “Scope Interface Specifications”