Page 4 of 59
Programmable On-board Pager Database
, Supporting 5,000+ pagers, and up to 10 Groups of 20
Pager IDs each, Stored in Non-Volatile EEPROM Memory. The Pager Database is “Not Required” for
WaveWare Protocol, Scope Protocol, Extended TAP Protocol, or Pager ID as Cap Code Mode.
Windows 32 bit Software, called “WaveWare Paging Encoder Setup” is provided for Pager Database
Programming, Com Port Settings, Range Testing, and General Messaging.
Programmable On-board Watchdog Timer
, To Keep the Paging System On-Line at All Times.
Programmable Verbose or Non-Verbose Modes
, Default is Verbose TAP. Verbose Output Means the
Paging System Responses Include more Information than Non-Verbose Responses.
Programmable Transmitter Duty Cycle Management
, In Percentage, from 0 to 100. Default is 50%
Duty Cycle. A 0 value also means 100%.
Remote Administration of Pager Database
, Pager Database can be “Modified” using Specially
Formatted TAP Paging Messages.
Programmable Timed Messaging Function
, Allowing the Paging System to Monitor the Host System,
and Automatically Deliver Alert Paging Messages if the Host System does not communicate to the
Paging System within a Two Minute Time Cycle. The Timer Triggered Messaging Function can be
Enabled or Disabled via Programming, and can be used as a Repetitive RF ping for Fully Supervised
Applications. Predefined Alert Messages can be up to 60 Characters in Length.
Programmable Maximum Batch
,
Size for Batch Messaging, Ranging from 1 to 32 Messages per
Batch. Batch Messaging allows Higher Message Throughput by Outputting a Single
POCSAG
Preamble for the Batch of Messages.
Default Max Batch is “10”
Programmable Pager ID as Capcode mode
, This Mode allows a Pager ID value in the COMP2 or TAP
Protocols to be treated as a Cap Code, allowing a Bypass of the Pager Database, and allowing
Direct Encoding of the Pager ID value as the Pager Cap Code. This Method Reduces Database
Configuration Efforts and Opens the Paging Encoder up to use of the Full Approximately 2 Million
POCSAG
Cap Code Values.
Programmable Carrier Detect Polarity
, Supports Integration of the WaveWare Paging Encoder to a
Variety of Radio Transmitters.
Choice of 0v or 5v
Default is “0v”
Programmable Data Encoding Polarity
, Supports on the Encoding of Messages:
Normal Polarity
Inverted Polarity
Default is “Normal”
Programmable Flow Control Signaling
, Choose either:
None
Hardware
Software
Alt Hardware (Flow before ACK/NAK)
*
Alt Software (Flow before ACK/NAK)
**
Default is “Hardware” (RTS/CTS)
Additional Information:
*
Alt Hardware (Flow before ACK/NAK):
**
Alt Software (Flow before ACK/NAK):