22
••
Installation
Stratum 100 Installation and Maintenance Guide
Step 5. Connecting to Ethernet
Connecting the Hardware
Note
: The MII port and 10Base-T port cannot both be used at the same time. Also, the AUI
port is only half duplex.
Attach a data cable (not provided) to the
100Base-TX port
on the Indoor Unit. . For a hub or
switch, use a straight through data cable. For a router use a crossover cable.
Install the snap-on ferrite filter
as close as possible to the rear panel RJ-45 connector
as
shown. This snap-on filter is required on the 10Base-T cable for FCC certification of the
Indoor Unit.
Plug the other end of this data cable into your network
.
Setting the Ethernet Parameters
From the System Administration Menu, use the down arrow to go to
Ethernet Config
and
press Enter to go to the Ethernet Configuration menu.
------------------------------ Ethernet Configuration -------------------------
System Status: OPERATE - CONNECTED - OK [ Alarms & Events.. ]
--------------------------- Physical Interface --------------------------------
Auto Negotiation: [Disabled]
Speed: [10 Mb ]
Duplex: [Half-Duplex]
Interface Type: [RJ45]
--------------------------- TCP/IP --------------------------------------------
IP Address: [192.168.3.202 ]
IP Subnet Mask: [255.255.255.0 ]
Default Gateway: [192.168.3.1 ]
--------------------------- Spanning Tree--------------------------------------
Spanning Tree State: [Enabled ]
Hello Time: [2 ] Bridge Priority: [32768]
Forward Delay: [15 ] Port Cost: [100 ]
Max Age: [20 ] Port Priority: [128 ]
[ ^Apply ] [ ^OK ] [ ^Cancel ]
-------------------------------------------------------------------------------
Use the down arrow to go the
Physical Interface
section of the screen. You must either
enable
Auto Negotiation
or specifically set the speed and duplex. (These fields are toggled
by pressing the space bar.) You must also specify the
Interface Type
(RJ45 or MII).
The IP address information in the
TCP/IP
section is only required if you will be accessing the
unit remotely via Telnet.
If you wish to use spanning tree, you can set those parameters now.
Press Ctrl A to save (apply) your changes. Use the down arrow to go to
OK
and press Enter
to leave this menu.
Connecting Ethernet to the Other IDU
Connect the Ethernet cable to the second IDU in the same manner as the first one. Use the
console port to set the Ethernet parameters.
Summary of Contents for Stratum 100
Page 1: ...Stratum 100 Wireless Ethernet Bridge Installation and Maintenance Guide...
Page 8: ......
Page 10: ......
Page 19: ...Stratum 100 Installation and Maintenance Guide Installation 11...
Page 29: ...Stratum 100 Installation and Maintenance Guide Installation 21 If there are Problems...
Page 35: ...Stratum 100 Installation and Maintenance Guide Installation 27 Step 8 Connecting to a PBX...
Page 36: ......
Page 64: ......
Page 66: ......
Page 67: ...Stratum 100 Installation and Maintenance Guide Index 59 Index Error No index entries found...