Thank you for your purchase of a state of the art Premier Reverse Osmosis (RO) water treatment system.

 Water quality 

concerns are becoming more of a focus for the public.  You may have heard about contaminants in the drinking water, such 
as Arsenic, Chromium, Cryptosporidium or Giardia.  There may also be some local water issues such as high levels of Lead 
and Copper. This Premier water treatment system has been designed and tested to provide you with high quality water for 
years to come.  The following is a brief overview of the system.

Your Reverse Osmosis System:

Osmosis is the process of water passing through a semi permeable membrane in order to balance the concentration of 
contaminants on each side of the membrane. A semi permeable membrane is a barrier that will pass some particles like clean 
water, but not other particles like arsenic and lead. 
Reverse osmosis uses a semi permeable membrane; however, by applying pressure across the membrane, it concentrates 
contaminants (like a strainer) on one side of the membrane, producing clean water on the other. This is why RO systems 

produce both clean drinking water and waste water that is flushed from the system. This reverse osmosis system also utilizes 

carbon block filtration technology, and can therefore provide much higher quality drinking water than carbon filtration systems. 

Your system is a Four Stage RO which is based upon four separate treatment segments within one complete water filtration 

system. These stages are as follows:
  

Stage 1 – Sediment filter, recommended change 6 months.

The first stage of your RO system is a five micron sediment filter that traps sediment and other particulate matter 

like dirt, silt and rust which affect the taste and appearance of your water. 

Stage 2 – Carbon filter, recommended change 6 months.

The second stage contains a 5 micron carbon block filter.  This helps ensure that chlorine and other materials that 

cause bad taste and odor are greatly reduced.  

Stage 3- Membrane, recommended change 2-5 years.

Stage three is the heart of the reverse osmosis system, the RO membrane.  This semi-permeable membrane will  take 
out TDS & Sodium and a wide range of contaminants such as Chromium, Arsenic, Copper, Lead, as well as Cysts, 
such as Giardia and Cryptosporidium and much more.  Because the process of extracting this high quality drinking 
water takes time, your RO water treatment system is equipped with a storage tank.  

Stage 4- VOC Block, recommend change 12 months.

Premier WP4V-50 reverse osmosis system conforms to NSF/ANSI 58 for VOC reduction. Through the specialty 

formulated VOC post filter your system is capable of reducing harmful Volatile Organic Chemicals (VOC) like 

MTBE’s, Atrazine, Benzene, 2,4-D,Lindane and others from your drinking water. It is estimated that VOC’s are 

present in one-fifth of the nation’s water supplies. These water contaminants can enter ground water from a variety 

of sources including localized use of herbicides and pesticides, gasoline or oil spills, leaking underground fuel tanks, 

septic system cleaners, and chemicals used in the dry-cleaning industry. See performance data sheet for individual 
contaminants and reduction performance. 

Note: 

Filter life may vary based upon local water conditions and/or use patterns.

System Maintenance

Just because you can not taste it, does not mean that it is not there. Contaminants such as lead, chromium, VOC’s and arsenic  

are undetectable to the taste.  Additionally, over time if you do not replace the filter elements, other bad tastes and odors will 

be apparent in your drinking water.  

This is why it is important to change out your filter at the recommended intervals as indicated in this system manual.  When 

replacing the filter elements, pay special attention to any cleaning instructions.    Should you have any further questions please 

refer to our website at 

www.premierH2o.com

 or call our customer service dept. at 

1-800-752-5582.

With proper installation and maintenance, this system will provide you with high quality water for years to come. 
All of Premier’s water enhancement products are rigorously tested by independent laboratories for safety and reliability.

If you have any questions or concerns, please contact our customer service department at 1-800-752-5582 

(outside USA 480-675-7995) or refer to our on-line troubleshooting guide at www.premierH2o.com.

Summary of Contents for Premier WP4V-50

Page 1: ...installation Your failure to follow any attached instructions or operating parameters may lead to the product s failure Watts Premier 8716 W Ludlow Drive Suite 1 Peoria AZ 85381 Phone 800 752 5582 www...

Page 2: ...RO membrane This semi permeable membrane will take out TDS Sodium and a wide range of contaminants such as Chromium Arsenic Copper Lead as well as Cysts such as Giardia and Cryptosporidium and much m...

Page 3: ...Installation 10 Drain Saddle Tube Connection 10 Reverse Osmosis Module Mounting 11 Green Tube Connection 11 Tank Elbow Installation 11 Connect Blue Tube from TANK Port on RO Module to the Tank 11 Con...

Page 4: ...Operating Pressure Maximum 100 psi 7 0 kg cm2 Minimum 40 psi 2 80 kg cm2 pH Parameters Maximum 11 Minimum 2 Iron Maximum 0 2 ppm TDS Total Dissolved Solids 1800 ppm Turbidity 5 NTU Hardness Maximum 1...

Page 5: ...1 104017 Sediment Filter 10 Inch 5M 4 ALT 1 560016 RO Membrane 35GPD 4 1 560018 RO Membrane 50GPD 5 3 113018 Filter Bowl 6 1 113035 Membrane Vessel 7 3 113041 O Ring Filter Bowl 8 1 113045 O Ring Mem...

Page 6: ...hen drilling Watts accepts no responsibility for damage resulting from the installation of faucet Diamond tip bit recommended Marble Counter top We recommend contacting a qualified contractor for dril...

Page 7: ...b and Install Spout Figure C This RO faucet is equipped with quick connect fittings for easy tube installation To connect tubes simply push them firmly into their corresponding fitting on the RO fauce...

Page 8: ...ur faucet will have a good seal Disassembling your faucet is never recommended as this could void your warranty If it is necessary to remove the fitting at the end of the toggle bolt you must follow t...

Page 9: ...Hot water will severely damage your system 3 8 Configuration With Brass Fittings Insert White Washer 1 2 Configuration Without Brass Fittings White Washer Hot Supply Cold Supply Hot Supply Cold Supply...

Page 10: ...e second drain Installation of the drain saddle near a garbage disposal may cause the drain line to plug If no other installation of drain line is available Premier offers drain line installation kit...

Page 11: ...quick connect fitting on the RO Manifold Make sure the tube is pushed in all the way to the tube stop See Picture Connect red faucet tube Green Tube Connection Step 14 Locate green tube attached to t...

Page 12: ...aucet to flush the tank completely You will know that the tank is empty when the flow rate from the RO faucet is down to a trickle Repeat this step two more times The fourth tank can be used for drink...

Page 13: ...pty to depressurize before attempting to remove filter housings Open the RO Faucet and allow water to drain from the tank until it is completely empty Insert the new Carbon Block filter White End Caps...

Page 14: ...inutes then continue rinsing eye Call a poison control center or doctor for treatment advice Step 4 With the RO faucet in the closed position turn on the incoming water supply to the system by turning...

Page 15: ...ntil it stops Follow the green tube away from the RO system to find the adapt a valve Step 2 Open the RO Faucet and allow water to drain from the tank until it is completely empty Step 3 Remove the ho...

Page 16: ...uge is recommended Check Air Pressure in the Tank Important Step 3 Check air pressure only when tank is empty of water Step 1 Turn off the incoming water supply to the RO Open the RO Faucet and allow...

Page 17: ...or drain Air gap faucet Inherent sound with air gap faucets Location of drain saddle See diagram for proper location of drain saddle Higher capacity membrane Normal with high capacity membrane High wa...

Page 18: ...omplete list of VOC s Recovery 13 7 Daily Production Rate 9 86 GPD Efficiency 6 8 Depending on water chemistry water temperature and water pressure Premier s R O Systems production and performance wil...

Page 19: ...ne where it does convert trivalent arsenic to pentavalent arsenic may not convert all the trivalent arsenic in to pentavalent arsenic If you get your water from a public water utility contact the util...

Page 20: ...ONITRILE 98 0 024 0 0006 DICHLOROACETONITRILE 98 0 0096 0 0002 TRICHLOROACETONITRILE 98 0 015 0 0003 HALOKETONES HK 1 1 DICHLORO 2 PROPANONE 99 0 0072 0 0001 1 1 1 TRICHLORO 2 PROPANONE 96 0 0082 0 00...

Page 21: ...urchase __________ Date of Install ___________ Installed by __________________ Serial No _____________________ Date 1st stage Sediment 6 months 2nd stage Carbon 6 months 4th stage VOC Block 1 year 3rd...

Page 22: ...exceed 105 degrees F 40 degrees C 7 Incoming TDS Total Dissolved Solids not to exceed 1800 ppm 8 Do not use with water that is micro biologically unsafe or of unknown quality without 9 adequate disinf...

Reviews: