1 Tank – White

1 Module – White

1 Parts Bag

1 Faucet Bag        

1 Filter Wrench

1 Manual

* All Filters Are Pre-Installed

      

Installation must comply with State and local plumbing regulations.  Do not use with water that is micro 
biologically unsafe or of unknown quality without adequate disinfection before or after the system. 
System is intended to be installed using the cold water supply only. 

Tools Recommended For Installation

√ 

1 1/4" Diamond Tipped Hole Saw bit for faucet opening (Counter Tops/Porcelain & Stainless Sinks)

√ 

1 1/4” Adjustable Wrench  

√ 

Phillips bit for electric drill

√ 

1/2" Open End Wrench   

√ 

Needle Nose Pliers

√ 

5/8” Open End Wrench   

√ 

Adjustable Pliers

√ 

Electric Drill 

 

 

√ 

Sharp Knife 

√ 

1/8" diamond tip bit, pilot hole 

√ 

Phillips Screw Driver

√ 

1/4” drain saddle hole   

Contents of the Reverse Osmosis (RO) System

Operating Temperatures:

Maximum 100

°

F (37.8°C)

Minimum 40°F (4.4°C)

Operating Pressure:

Maximum 100 psi (7.0 kg/cm

2

)

Minimum 40 psi (2.80 kg/cm

2

)

pH Parameters:

Maximum 11

Minimum 2

Iron:

Maximum 0.2 ppm

TDS (Total Dissolved Solids)

< 1800 ppm

Turbidity

< 5 NTU

Hardness

Maximum 10 Grains Per Gallon 

*

Hardness: 

Recommended hardness not to exceed 10 grains per gallon, or 170 parts per million.  

*  

System will operate with hardness over 10 grains but the membrane life may be shortened.    

 

   Addition of a water softener may lengthen the membrane life.

Copper Tube: 

Reverse Osmosis water should not be run through copper tube as  the purity of the 

water will leach copper causing an objectional taste in water and pin holes may form in the tube.

Water Pressure: 

The operating water pressure in your home should be tested over a 24 hour 

period to attain the maximum pressure.  If the incoming water pressure is above 100 psi then a 

water pressure regulator is required. A booster pump is needed for incoming water pressure 

under 40psi.

Operational Parameters

INSTALLATION & STARTUP

If any of the items are missing please contact Premier prior to installing.

Summary of Contents for Premier WP4V-50

Page 1: ...installation Your failure to follow any attached instructions or operating parameters may lead to the product s failure Watts Premier 8716 W Ludlow Drive Suite 1 Peoria AZ 85381 Phone 800 752 5582 www...

Page 2: ...RO membrane This semi permeable membrane will take out TDS Sodium and a wide range of contaminants such as Chromium Arsenic Copper Lead as well as Cysts such as Giardia and Cryptosporidium and much m...

Page 3: ...Installation 10 Drain Saddle Tube Connection 10 Reverse Osmosis Module Mounting 11 Green Tube Connection 11 Tank Elbow Installation 11 Connect Blue Tube from TANK Port on RO Module to the Tank 11 Con...

Page 4: ...Operating Pressure Maximum 100 psi 7 0 kg cm2 Minimum 40 psi 2 80 kg cm2 pH Parameters Maximum 11 Minimum 2 Iron Maximum 0 2 ppm TDS Total Dissolved Solids 1800 ppm Turbidity 5 NTU Hardness Maximum 1...

Page 5: ...1 104017 Sediment Filter 10 Inch 5M 4 ALT 1 560016 RO Membrane 35GPD 4 1 560018 RO Membrane 50GPD 5 3 113018 Filter Bowl 6 1 113035 Membrane Vessel 7 3 113041 O Ring Filter Bowl 8 1 113045 O Ring Mem...

Page 6: ...hen drilling Watts accepts no responsibility for damage resulting from the installation of faucet Diamond tip bit recommended Marble Counter top We recommend contacting a qualified contractor for dril...

Page 7: ...b and Install Spout Figure C This RO faucet is equipped with quick connect fittings for easy tube installation To connect tubes simply push them firmly into their corresponding fitting on the RO fauce...

Page 8: ...ur faucet will have a good seal Disassembling your faucet is never recommended as this could void your warranty If it is necessary to remove the fitting at the end of the toggle bolt you must follow t...

Page 9: ...Hot water will severely damage your system 3 8 Configuration With Brass Fittings Insert White Washer 1 2 Configuration Without Brass Fittings White Washer Hot Supply Cold Supply Hot Supply Cold Supply...

Page 10: ...e second drain Installation of the drain saddle near a garbage disposal may cause the drain line to plug If no other installation of drain line is available Premier offers drain line installation kit...

Page 11: ...quick connect fitting on the RO Manifold Make sure the tube is pushed in all the way to the tube stop See Picture Connect red faucet tube Green Tube Connection Step 14 Locate green tube attached to t...

Page 12: ...aucet to flush the tank completely You will know that the tank is empty when the flow rate from the RO faucet is down to a trickle Repeat this step two more times The fourth tank can be used for drink...

Page 13: ...pty to depressurize before attempting to remove filter housings Open the RO Faucet and allow water to drain from the tank until it is completely empty Insert the new Carbon Block filter White End Caps...

Page 14: ...inutes then continue rinsing eye Call a poison control center or doctor for treatment advice Step 4 With the RO faucet in the closed position turn on the incoming water supply to the system by turning...

Page 15: ...ntil it stops Follow the green tube away from the RO system to find the adapt a valve Step 2 Open the RO Faucet and allow water to drain from the tank until it is completely empty Step 3 Remove the ho...

Page 16: ...uge is recommended Check Air Pressure in the Tank Important Step 3 Check air pressure only when tank is empty of water Step 1 Turn off the incoming water supply to the RO Open the RO Faucet and allow...

Page 17: ...or drain Air gap faucet Inherent sound with air gap faucets Location of drain saddle See diagram for proper location of drain saddle Higher capacity membrane Normal with high capacity membrane High wa...

Page 18: ...omplete list of VOC s Recovery 13 7 Daily Production Rate 9 86 GPD Efficiency 6 8 Depending on water chemistry water temperature and water pressure Premier s R O Systems production and performance wil...

Page 19: ...ne where it does convert trivalent arsenic to pentavalent arsenic may not convert all the trivalent arsenic in to pentavalent arsenic If you get your water from a public water utility contact the util...

Page 20: ...ONITRILE 98 0 024 0 0006 DICHLOROACETONITRILE 98 0 0096 0 0002 TRICHLOROACETONITRILE 98 0 015 0 0003 HALOKETONES HK 1 1 DICHLORO 2 PROPANONE 99 0 0072 0 0001 1 1 1 TRICHLORO 2 PROPANONE 96 0 0082 0 00...

Page 21: ...urchase __________ Date of Install ___________ Installed by __________________ Serial No _____________________ Date 1st stage Sediment 6 months 2nd stage Carbon 6 months 4th stage VOC Block 1 year 3rd...

Page 22: ...exceed 105 degrees F 40 degrees C 7 Incoming TDS Total Dissolved Solids not to exceed 1800 ppm 8 Do not use with water that is micro biologically unsafe or of unknown quality without 9 adequate disinf...

Reviews: