Benchmark Platinum-Edge: Operation-Service Manual
SECTION 8 – MAINTENANCE
OMM-0137_D • GF-211
•
7/16/2019
Technical Support
•
(800) 526-0288
•
Mon-Fri, 8 am - 5 pm EST Page 101 of 146
Figure 8-1b: Igniter-Injector & Flame Detector (BMK 1500/3000)
Figure 8-1c: Igniter-Injector & Flame Detector (BMK 2500/3000)
Figure 8-1d. Igniter-Injector Orientation (BMK 2500/3000 Shown)
BLOWER
PLENUM
IGNITER-
INJECTOR
ASSEMBLY
FLAME
DETECTOR
FLAME
OBSERVATION
PORT
O
2
SENSOR
BLOWER
PLENUM
IGNITOR-INJECTOR
ASSEMBLY
FLAME
DETECTOR
BURNER
FLAME OBSERVATION PORT
O
2
SENSOR
BURNER
O2 SENSOR
IGNITER-INJECTOR
INJECTOR TUBE
POSITION
INJECTOR TUBE
INSIDE THIS ARC
(towards blower
plenum)