Explanation of Function
Seite 154 / 180
Explanation
Data size
Value
STX
Control code(Start of TeXt)
1 byte
STX (0x02)
Code
Station number of inverter
2 byte
01-32
Data
Data on trip
8 byte
(Note7) reference
BCC
Block check code
2 byte
Exclusive OR of Code, Command
and Data
(5) Reference
CR Control
code(Carriage
Return)
1 byte
CR (0x0D)
The data to indicate status contents of inverter is constructed from the following three factors [A), B),
C)].
Data
Inverter status A)
Inverter status C)
Inverter status B)
Code Status
00 Initial
status
01 Vdc on waiting
settlement
02 On
stopping
03 On
running
04 On
FRS
05 On
JG
06 On
DB
07
On reading frequency
08 On
retrying
09 On
UV
10 On
TRIP
Code
Status
00 ---
01 Stop
02 Deceleration
speed
03 Constant
speed
04 Acceleration
speed
05 Forward
06 Reverse
07 Reverse from
forward
08 Forward from
reverse
09
Forward start
Status A
Status B
Status C
00 (reservation)