Table 16 - Acyclic data records
ADI /
Index in
decimal
Name
Access
Type
Description
81
Edit active recipe
name
Write
Unsigned8 array length
13 including NULL
terminator (OctetString)
Edit the name of the recipe
in the active batch
94
Active batch
name
Read
Unsigned8 array length
13 including NULL
terminator (OctetString)
Read the active batch name
95
Active recipe
name
Read
Unsigned8 array length
13 including NULL
terminator (OctetString)
Read the active recipe name
19.5
GSDML compatibility guide
Table 17 - GSDML compatibility guide
GSDML file (Found on website)
GSDML
release
Date
Pump
Models
Compatible with
pump software
versions
Version
comments
GSDML-V2.4-Watson Marlow-530_
630_730 Profinet Pump-
20211116.xml
January
2021
530Pn,
630Pn,
730Pn
0.41.03
Initial
GSDML release
Link to GSDML file location:
1.
Navigate to:
https://www.wmftg.com/en/literature/other-resources/software-and-devices/
Notes:
1.
If your pump software is compatible with multiple GSDML files versions it is recommended to
use the latest version available.
2.
In order to find your pump software version, select
Help
, then
Software
on your pump
3.
The correct GSDML file version must be used in combination with the pump software versions
listed for good communication between the pump and control system.
4.
Networks using pumps with different software and GSDML versions are acceptable as long as
each pump is using the correct GSDML version
m-530pn-en-09 02-02-22