20.6
Dispense time delays diagram
1
2
2
3
3
2
4
3
A
C
B
Figure 20 - Dispense time delays
A
Batch
(Note: diagrams shows a batch size of three.)
B
Pump is stopped
C
Pump is dispensing
1
Batch start delay ("Start delay (batch)" on page 107)
2
Recipe start delay ("Start delay (Recipe)" on page 108)
3
Recipe end delay ("End delay (Recipe)" on page 108)
4
Batch end delay ("End delay (batch)" on page 107)
21
Dispense with PROFINET® control
1.
Add a recipe and batch using the HMI on the pump by following the procedure in "Create a
new recipe or edit a recipe" on page 94 and "Create a new batch or edit a batch" on page 98
2.
Leave the pump in
Dispense
mode and have the correct batch active ("Set the active batch"
3.
Lock the control of the pump using the PIN function ("PIN protection" on page 43)
4.
Start/stop the pump using PROFINET® control.
22
Sensors
Sensors can be connected to the pump to display the value, warnings and errors on pressure and or
flow as selected.
Attached sensors allow the user to configure warning and alarm set points on the pump.
Each pump can support a maximum of one flow sensor and one pressure sensor at the same time.
110