PROFINET (Industrial Ethernet) connection
There are two communication connectors on the rear of the N Module for PROFINET (Industrial
Ethernet) connection (3,4). Both connectors have the same pin configuration. The pin configuration
and the signal response is shown below.
Plugs and cables for these connectors should be: M12, male, 4-Pin D coded, shielded.
1
2
3
4
TX+
RX+
RX-
TX-
Figure 14 - Ethernet connection
Adapter PCB
Figure 15 - Adapter PCB
1.
2.
U1
1.
Without isolated power supply option
(N Module)
2.
With isolated power supply option
(F Module)
Note: Disconnect the adapter module by use of the ribbon eject levers. It is recommended to leave
the 9W connector permanently attached to the pump.
Recommended control cable: metric = 0.05 sq mm - 1.31 sq mm solid and stranded. USA = 30AWG -
16AWG solid stranded. Cable: circular. Max/min outside diameter to ensure a seal when passed
through the standard gland: 9.5 mm-5 mm.
The cable section must be circular to ensure a seal
.
28