5 - Error Conditions, Problems and Solutions - Book Quality Problems
62
Watkiss PowerSquare™224 User Manual
Is the number of
STITCHES
set between 1 and 6?
Yes No
Select
STITCHES
1 - 6. See “STITCHES” on page 20.
Check the stitch-wire spool. Is there stitch-wire present?
Yes No
Load a new stitch-wire spool. See “Install New Stitch-wire” on page 116.
Open the PSQ main deck. See “Lift the PowerSquare Main Deck” on page 36.
Pull approximately 100-150mm of stitch-wire from the stitch wire spool. See Fig-
ure 37 on p.61.
Does the wire move freely?
Yes No
Open the stitch-wire cabinet.
Discard any tangled wire and reload the stitch-wire spool. See “Install New
Stitch-wire” on page 116.
Check the stitch head for stitch-wire jams. See Figure 38 on p.61.
Is the stitch head clear of stitch-wire jams?
Yes No
Clear the stitch-wire jam. See “Clear a Stitch-wire Jam” on page 92.
Lubricate the stitch head. See “Lubricate the Stitch Head” on page 111.
Does the problem continue?
Yes No
Further action is not needed.
Call your service engineer